Yamaha 2008 YW50X Service Manual page 252

Table of Contents

Advertisement

AUTO O.O.E S STEM IE'Ecl
I
YP...
2. Auto choke unit resistance
• Disconnect the auto choke unit coupler
from the wireharness.
• Connect the pocket tester ( ~ x l ) to the auto
choke unit coupler lead.
Tester (+) l e a d . B l a c k terminal (~
Tester (-) lead->Black terminal (~
~ _ ~
Auto choke unit resistance:
8~12~ at 20°C
(68°F)
~ M E E T S
SPECIFICATION
3. Wiring connection
• Check the connection of the entire auto
choke system.
Refer to "CIRCUIT DIAGRAM" section.
OUT OF SPECIFICATION
I Replace the auto choke unit.
POOR CONNECTION
I Correct.
7-44

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents