68
67
69
71
60
61
62
66
67
70
72
73
O
P
Injection pump installation and setting injectors
(mechanical injection engine)
(mechanical injection engine)
(mechanical injection engine)
(mechanical injection engine)
(mechanical injection engine)
Installation injecting pump
1) Align mark (60) of the camshaft and (61) of the cylinder
head cover. Be sure of the alignment between hole (66) of
pulley (62) of the auxiliary organs group and hole of the block
using tool ref. 790965.
NOTE:
If injection pump bushing (67) requires substitution, use
tool ref. 790992 to avoid turning of the bushing during
removal or installation (68). To extract bushing use tool
ref. 790991.
2) Install injection pump in housing of the auxiliary organs group
as follows:
• Put into coincidence channel (69) of the driving shaft with
guiding tooth (70) of the bushing (67) and install the pump.
• Align the marks done during removal on the sump of the
injection pump and on the sump of the auxiliary organs
group ( ). Assemble nuts (71) fixing without tightening
too much.
Injecting pump setting.
3) Disconnect K.S.B device (72) supplying a 12 volts tension on
terminal (73); supply must be ON while setting up the pump.
NOTE:
The K.S.B. device is disactivated when the advancing
lever is no submitted to loading.
ENGINE REPAIR 6A-141