Security Codes

The VISTA-20P system supports up to 48 security codes (VISTA-15P supports 32 codes), which can
each be assigned one of 5 authority levels. The authority level determines the functions each code
can perform as follows:
Authority Levels
Level
User No.
Installer
01
System
02
Master
Partition
P1 = 03
Master
P2 = 33
(default)
0-User
03-49
03-33
1-Arm Only see "user"
2-Guest
see "user"
3-Duress
see "user"
4-Partition
see "user"
Master
Refer to the user guide for detailed procedures on adding/deleting security codes and changing user
attributes.
The following is a brief description of how to add user codes.
Adding a User Code:
Deleting a User Code: Master code + [8] + 2-digit user no. + [#] [0]
Assigning Attributes: Master code + [8] + 2-digit user no. + [#] [attribute no.] + value
(authority levels can be assigned to users 3-49 only; users 1 and 2 cannot be changed)
Functions
(default=4112) perform all security functions except can disarm only if
used to arm; can enter program mode; can change System Master code;
cannot assign any other user codes
(default 1234) only one system master code per system; can perform all
security functions, add/delete users in either partition, change system
master code, view event log, set system clock, program keypad macro,
program scheduled events, activate output devices (triggers/relays)
VISTA-20P. Same as Master, except add/delete users limited to
assigned partition only, (these users can be assigned different authority
levels, if desired; any user can be assigned the partition master authority
level)
perform security functions (arm, disarm, etc.) only; cannot add/delete
)
(V20P
users, view event log, set system clock or program scheduled events
(V15P)
arm system only
can disarm the system only if it was used to arm the system
performs security functions, but also silently sends a duress message to
the central station; reports as duress code user number.
VISTA-20P. See Partition Master paragraph above; used to assign
other user numbers as partition masters
Master code + [8] + 2-digit user no. + user's code
Attributes:
1 = Authority Level
2 = Access Group
3 = Active Partition(s)
for this user;
4 = RF Zone No.
5 = Open/Close Paging

System Operation

Values
0-4 (see Authority Level table above)
0-8 (0 = not assigned to a group)
1, 2, 3 (common)
Enter partitions consecutively if more than one
and press [#] to end the entries.
Assigns user number to button type zone for
arm/disarm (keyfob must be enrolled in
system first; see Wireless Key Templates
section).
1 for yes, 0 for no
S E C T I O N
1 2
12-1

Hide quick links:

Advertisement

Table of Contents
loading