V.24 Interface Option

The ErgoLine D340 terminal has an optional V.24 Data Interface. This interface
conforms to the CCITT V.24/V28 recommendations for, respectively, the circuit
functions and electrical characteristics.
The V.24 Data Interface is an ISDN terminal adapter which enables
communication with a similar device. It is not designed to communicate with
modems, although modem commands can be used to control it. The V.24
interface behaves as a DCE and the connected V.24 equipment behaves as a
DTE.
Note: The V.24 option requires an external power supply to be fitted.
Installing the V.24 Data Interface
To install a Data Interface in the ErgoLine terminal, proceed as follows:
WARNING: Do not open the ErgoLine terminal when either the line or
external power supply are connected.
1. Turn the terminal upside down.
2. Remove the line cord (if connected).
3. Remove the DSS/DSS. This is attached by two screws in the base of the
terminal.
4. Remove the external power supply (if fitted).
5. Remove the handset plug and any auxiliary equipment fitted to the audio or
static interface.
6. Remove the base of the terminal. A few screws fasten the base to the terminal.
One of the screws is located under the DSS cover.
7. Install the V.24 Data Interface as shown.
F
2-5. I
IGURE
NSTALLING THE
ErgoLine D330/D340
Customer Engineer Manual
V.24 I
NTERFACE
Page 2-31