CEBORA S.p.A.

3.2.2 - Power source operation.

Operations preceded by this symbol refer to operator actions.
♦ Operations preceded by this symbol refer to machine responses that must occur following an
operator action.
System shut off and disconnected from the mains.
Connect the gas intake to the fitting (T) on the rear panel.
Connect the torch to the central adapter (E) of the power source (with push-pull torch also
connect the patch connector of the torch to the connector (S) of the power source).
Connect the negative pole cable (F) of the power source to the workpiece.
Connect the power source to the mains.
Close the switch (U).
♦ System supplied, on control panel leds and displays lit (lamp test).
♦ After one second, display (G) indicates "Hxx" (H = conventional, synergic and
non synergic programs tables; xx = the version of the programs (see tables 2.8.1
and 2.8.2)). Display (Q) indicates the version of the "firmware 285 Cebora".
♦ After one second, display (G) indicates "Pxx" (P = pulsed synergic programs
table; xx = the version of the programs (see table 2.8.3)). Display (Q) indicates the
version of the "firmware 285 Cebora".
♦ After one second, display (Q) indicates the selected working program, and display
(G) indicates the corresponding material type. Some indicator leds remain lit; all
as they were set before the last time the unit was shut off.
♦ Fan (24) working.
♦ After two seconds, display (Q) indicates the selected working program, and
display (G) indicates the wire speed if a "conventional non-synergic" program is
selected, or the programmed current or wire speed (depending of the "dSp"
function set-up) if a "synergic" program is selected.
Press the button (O) several times; the "Program" selection is repeated in sequence.
Press the button (R) several times; the "Program" selection is repeated in sequence.
♦ Each time the button (O) is pressed, the number indicated by display Q increases.
♦ Each time the button (R) is pressed, the number indicated by display Q decreases.
♦ Each time the buttons (O) or (R) is pressed, display (G) indicates the type of
material set in the program shown on display (Q). After two seconds display (G)
indicates the wire speed if a "conventional non-synergic" program is selected, or
the programmed current or wire speed (depending of the "dSp" function set-up) if
a "synergic" program is selected.
Press the button (O) and (R) simultaneously to enter in set-up mode.
Press the torch start button several times; set-up functions selections is repeated in sequence.
3.302.161
NOTE
Correct?
NO (see 3.3.1, 3.3.2, 3.3.3).
YES
Correct?
NO (see 3.3.3).