20 Heat Set Point Upper Limit – Selects the heating set point upper adjustment limit.
21 Cool Set Point Lower Limit
[note
6] – Selects the cooling set point lower adjustment limit.

5 System Testing

Warning
Read Before Testing
• Do not short (or jumper) across terminals on the gas valve or at the heating or cooling system control board
to test the thermostat installation. This could damage the thermostat and void the warranty.
• Do not select the COOL mode of operation if the outside temperature is below 50º F (10º C). This could
possibly damage the controlled cooling system and may cause personal injury.
• This thermostat includes an automatic compressor protection feature to avoid potential damage to the
compressor from short cycling. When testing the system, make sure to take this delay into account.
NOTE: The compressor delay can be bypassed by pressing the reset button on the front of the thermostat.
All user settings will be returned to factory default, however all Installer settings will remain as originally
programmed in section 4.
1 Press the SYSTEM button until the thermostat is in HEAT mode.
2 Using the SpeedBar
raise the set temperature a minimum of 3 degrees above the current room
®
temperature. The system should start within a few seconds. With a gas heating system, the fan may
not start right away.
3 Press SYSTEM until the thermostat is in the OFF mode. Allow the heating system to fully shut down.
4 Press SYSTEM until the thermostat is in the COOL mode.
5 Using the SpeedBar lower the set temperature a minimum of 3 degrees below the current room
temperature. The system should start within a few seconds (unless compressor short cycle protection
is active – See note above).
6
Press SYSTEM until the thermostat is in the OFF mode. Allow the cooling system to fully shut down.
7
Press FAN until the thermostat is in FAN ON mode. The system fan should start within a few seconds.
8
Press FAN until the thermostat is in FAN AUTO mode. Allow the system fan to turn off.
12
Installer Guide

Limited Warranty

When installed by a professional contractor, this product is backed by a 5 year limited
warranty. Limitations apply. For limitations, terms and conditions, you may obtain a full
copy of this warranty:
· Visit us online: www.braeburnonline.com/warranty
· Phone us: 866.268.5599
· Write us: Braeburn Systems LLC
2215 Cornell Avenue
Montgomery, IL 60538
Store this manual for future reference.
Braeburn Systems LLC
2215 Cornell Avenue • Montgomery, IL 60538
Technical Assistance: www.braeburnonline.com
Call us toll-free: 866-268-5599 (U.S.)
630-844-1968 (Outside the U.S.)
©2012 Braeburn Systems LLC • All Rights Reserved • Made in China.
®
®
5
YEAR
LIMITED
WARRANT Y
3020W-100-01

Advertisement

loading

This manual is also suitable for:

3220