Non-Programmable Thermostats
3020 Single Stage Conventional Systems
or Single Stage Heat Pumps with Auxiliary Heat
3220 Up to 3 Heat / 2 Cool Heat Pump
Up to 2 Heat / 2 Cool Conventional
Model number is located on back of thermostat.
1 Specifications
2 Installation and Wiring
Warning
For installation by experienced service technicians only.
Caution
• Possible electric shock or damage to equipment can occur.
• Disconnect power before beginning installation.
This thermostat requires 24 Volt AC Power or 2 properly installed "AA" Alkaline batteries for
proper operation. When connecting 24 Volt AC Power the batteries may be installed as a backup.
For use only as described in this manual. Any other use will void warranty.
Visit www.braeburnonline.com for detailed Installer Guide.
1 Specifications
This thermostat is compatible with:
• Single stage heat / cool conventional and heat pump systems
• Single stage heat pumps with auxiliary heat
• Conventional systems up to 2 stages of heating and 2 stages of cooling (3220 only)
• Heat pump systems up to 3 stages of heating and 2 stages of cooling (3220 only)
• 250 – 750 millivolt heating only systems
• 2 or 3 wire hydronic zone systems
Electrical and control specifications:
• Electrical Rating: 24 Volt AC
• 1 amp maximum load per terminal
• AC Power: 18 – 30 Volts AC
• DC Power: 3.0 Volt DC
(2 "AA" Alkaline Batteries Included)
• Control Range: 45° – 90° F (7° – 32° C)
• Temperature Accuracy: +/- 1° F (+/- .5° C)
• Outdoor Temperature Display Range: -40° - 120° F (-40° - 49° C)
®
3 Quick Reference
4 Installer Settings
Terminations
• 3020: G, Rc, Rh, W1/E, O/B/V3, Y1, C, S1, S2
• 3220: G, Rc, Rh, W1/E/W3, W2, O/B/V3, Y1,
Y2, C, L, S1, S2
P
REMIER
S
ERIES
3020-100-03

Advertisement

Table of Contents
loading

Summary of Contents for Braeburn 3020

  • Page 1 Electrical and control specifications: Terminations • Electrical Rating: 24 Volt AC • 3020: G, Rc, Rh, W1/E, O/B/V3, Y1, C, S1, S2 • 1 amp maximum load per terminal • 3220: G, Rc, Rh, W1/E/W3, W2, O/B/V3, Y1, • AC Power: 18 – 30 Volts AC Y2, C, L, S1, S2 •...
  • Page 2: Installation And Wiring

    Installation and Wiring Install your new Braeburn thermostat in 4 basic steps: 1 Install the sub-base 3 Connect your wires 2 Provide Power 4 Attach the thermostat to the sub-base Install the Sub-Base: Provide Power • Remove the sub-base from the body of the thermostat.
  • Page 3 Connecting Your Wires (continued) Wiring Terminations for model 3220 Terminal Function Description Input 24 Volt AC Cooling Transformer (Dual Transformer Systems Only) Input Power Connection (24 Volt AC Heating Transformer or Millivolt Power Source) Output Fan Control W1 / E / W3 Output (W1) 1st Stage Conventional Heat, (E) Emergency Heat,...
  • Page 4: Conventional Systems

    Conventional Systems Typical Wiring Configurations NOTE: The “System Type” option will be configured in the Installer Settings section. Shaded areas do not apply to the 3020. Heat Only or Millivolt 1 HEAT / 1 COOL Single or Dual Transformer Set System Type to 11CONV...
  • Page 5: Heat Pump Systems

    Heat Pump Systems - Typical Wiring Configurations NOTE: The “System Type” option is configured in the Installer Settings. Shaded areas do not apply to 3020. 1 HEAT / 1 COOL - No Auxiliary Heat 2 HEAT / 2 COOL - No Auxiliary Heat...
  • Page 6: Attach Thermostat To Sub-Base

    NOTE: Additional options are configured in the NOTES - Additional Wiring Options Installer Settings section. [1] These terminals can be used to connect a Braeburn indoor or outdoor remote sensor. ® Indoor or Outdoor Remote Sensor [note 1] Attach Thermostat to Sub-Base INSTRUCTIONS 1) Line up the thermostat body with the sub-base.
  • Page 7: Quick Reference

    Outdoor Temperature Indicator..Displays along with the outdoor temperature reading (see note below) Installer Clear Button ....Located on back of thermostat body – clears all settings Battery Compartment ....Located in the back of thermostat NOTE: If a Braeburn outdoor sensor was connected you can view the outdoor temperature by ®...
  • Page 8: Installer Settings

    ® NEXT BACK 4. Press to move to the next or previous setting, press RETURN to exit. NOTE: Shaded areas below do not apply to the 3020. No. Installer Setting Factory Setting Comments Default Options Notes follow this table) (More information follows this table)
  • Page 9 Select a Cool Set Point Lower Limit of 45°-80° F [note 6] (7.0°-27° C) BACK NEXT *When a Braeburn outdoor sensor is connected, the thermostat automatically recognizes it. Press at the ® same time to display outdoor temperature. NOTE: Additional options such as Service Monitors, Setting the lock code, etc. are located in the User Settings –...
  • Page 10 ® 8 Only available if auto changeover was enabled in option 2. 9 Only available if a Braeburn outdoor sensor was connected. Detailed Explanation of Installer Settings (also see NOTES above): Temperature Scale – Selects a temperature scale of either °F or °C.
  • Page 11 (I SENS), remote sensor only (E SENS) or combining the thermostat and the remote sensor (A SENS). NOTE: This option does not apply to a Braeburn outdoor sensor. When an outdoor sensor is connected the thermostat automatically recognizes it and no further configuration is necessary.
  • Page 12: System Testing

    5 System Testing Warning Read Before Testing • Do not short (or jumper) across terminals on the gas valve or at the heating or cooling system control board to test the thermostat installation. This could damage the thermostat and void the warranty. •...
  • Page 13: Limited Warranty

    Store this manual for future reference. ® Braeburn Systems LLC 2215 Cornell Avenue • Montgomery, IL 60538 Technical Assistance: www.braeburnonline.com Call us toll-free: 866-268-5599 (U.S.) 630-844-1968 (Outside the U.S.) 3020-100-03 ©2016 Braeburn Systems LLC • All Rights Reserved • Made in China.