Design Guide (For Zifi240 And Zibi240); The Installation Space; Product Clearances; Side-By-Side Installations - Monogram ZIFI240 Installation Instructions Manual

Fresh-food refrigerator; bar refrigerator with icemaker
Table of Contents

Advertisement

For models ZIFI240 and ZIBI240 with Custom Door Panels and Handles

THE INSTALLATION SPACE

Locate
Outlet
8-1/2"
10-1/2"
9"
9" Max.
34-1/2"-35"
Max.
1-1/2"
1-1/2"
23-3/4" Min.
NOTE:
Handle is
not supplied.*
*Custom handle clearances may vary,
depending on the standoff of the custom handle.
The cutout depth should be 24"
The cutout dimensions shown allow for a full door
swing and access to the pull-out racks when installed
in standard 24" deep cabinets.
• The Fresh-Food Refrigerator or Bar Refrigerator with
Icemaker can be installed freestanding.
• In a standard 24" opening, the refrigerator door will
protrude 1-3/4" forward of the adjacent cabinets.
Additional Specifications
• A 120 volt 60Hz., 15 or 20 amp power supply is
required. An individual properly grounded branch
circuit or circuit breaker is recommended. Install a
properly grounded 3-prong electrical receptacle
recessed into the back wall as shown. Electrical must
be located on rear wall as shown. NOTE: GFCI (ground
fault circuit interrupter) is not recommended.

SIDE-BY-SIDE INSTALLATIONS

For a complete refreshment center, install a Fresh-Food Refrigerator
beside a Double Drawer Refrigerator, Beverage Center or Wine
Chiller/Wine Reserve. Or, install a Refrigerator with Icemaker beside
a Wine Chiller/Wine Reserve.
• A side-by-side installation requires at least a 47-1/2" wide opening.
No trim kits required.
• Products must operate from separate, properly grounded receptacles.
Design Guide
NOTE:
24"
Water line location
for ZIBI240 or
ZIBS240 model only
34-1/2"
24-7/8"
23-3/4"

PRODUCT CLEARANCES

The Fresh-Food Refrigerator or Bar Refrigerator with
Icemaker is factory set for a 110° door swing.
When installed in a corner:
• Allow 16" minimum clearance on the hinge side
for a full 110° door swing.
• Allow 4-1/2" min. clearance on the hinge side for
the 90° door swing and to allow racks to slide out.
NOTE: Custom handle clearances may vary, depending
on the standoff of the custom handle.
16" Minimum to Wall
110° Door
Swing
110°
• Test the door swing. Carefully open and close the
door. The door should not rub or catch on adjacent
cabinetry. Notify the installer if the door makes
contact with cabinetry. NOTE: When installing
custom panel and handle, use above clearances as a
general guide but adjust according to the installation.
Choose the location:
• These products may be closed in on the top and
three sides as long as the front is unobstructed for
air circulation and proper access to the door.
• Do not install these products where the temperature
will go below 55°F (13°C) or above 90°F (32°C).
• These products are not designed to be stacked one
over the other.
Black or Stainless Steel Toekick Options
• These products are shipped with two toekicks: a stainless
steel toekick and a black toekick. For shipping purposes,
one of the toekicks will be secured to the back of the
unit, and the second will be installed, in place, on the
unit. Keep the unused toekick, and other unused or
removed parts, for future use.
34-1/2"-35"
5
90° Door
21-5/8"
Swing
23-5/8"
90°
4-1/2" Minimum to Wall
Locate
Outlet
10-1/2"
10-1/2"
24"
14"
9"
9"
15"
1-1/2"
47-1/2" Min.