-- With the main burner in operation, check all
connections, hose connections, fittings and
joints as well as the gas control valve inlet and
outlet connections with approved gas leak
detectors.
-- If a leak is detected, check the components
involved for cleanliness in the thread areas and
proper application of pipe compound before
further tightening.
-- Tighten the gas connection as necessary to
stop the leak.
-- If necessary, replace the parts or components
involved if the leak cannot be stopped.
-- Ensure all gas leaks have been identified and
repaired before proceeding.
9. A qualified service agency must check for proper
operating gas pressure upon installation of the heater.
10. Light according to instructions on heater or within
owner's manual.
Connect end of hose with nut to safety control valve at
heater. See Fig. 2. Tighten securely.
FIG. 2
HOSE AND REGULATOR ARE
PREASSEMBLED
1. Remove the plastic cap from the POL fitting. Do not
discard the cap. Position the regulator as shown.
2. Inser t the POL fitting into the propane supply
container's valve. See Fig. 3. Thread nut on fitting
counterclockwise into propane supply valve. Tighten
nut securely with a wrench.
-- When storing or transporting the heater, ensure the
cap is pushed onto the POL fitting to prevent
damage or dirt entry into regulator.
11. Make sure the heater has the proper gas regulator for
the application. A regulator must be connected to the
gas supply so that gas pressure at the inlet to the gas
valve is regulated within the range specified on the
dataplate at all times. Contact your gas supplier, or
the L.B. White Co., Inc. if you have any questions.
12. This heater is configured for use with propane vapor
withdrawal only. Consult the heater's dataplate for the
gas configuration of the specific heater. Do not use
the heater in an propane liquid withdrawal system or
application. If you are in doubt, contact the L.B. White
Co., Inc.
13. Take time to understand how to operate and maintain
the heater by using this Owner's Manual. Make sure
you know how to shut off the gas supply to the heater.
Contact your fuel gas supplier if you have any
questions.
14. Any defects found in performing any of the service or
maintenance procedures must be eliminated and
defective parts replaced immediately. The heater
must be retested by properly qualified ser vice
personnel before placing the heater back into use.

HOSE AND REGULATOR ASSEMBLY

CONNECTING REGULATOR TO GAS SUPPLY

Ensure regulator is installed under a protective cover
FIG. 3