  • Page 1 Slide Gate Operator UL325 - UL991 FAAC International Inc. FAAC International Inc. West Coast Operations Headquarter & East Coast Operations 357 South Acacia Avenue 5151 Sunbeam Road Unit 357 Suites 9-11 Fullerton, CA 92831 Jacksonville, FL 32257 Tel. (800) 221-8278...
  • Page 2: Table Of Contents

    Read and follow all U.L. and Safety Standards before installing any access device. Please refer to this manual and qualified personnel for assistance. DO NOT install this device unless all entrapment and pinch points are eliminated. FSL700 Slide Gate Operator...
  • Page 3: Important User Instructions

    Proper reversing devices MUST be installed on all gates to avoid all potential hazards and entrapment. 9. SAVE THESE INSTRUCTIONS FSL700 Slide Gate Operator...
  • Page 4: Important Safety Information

    OF A MOVING GATE! in the gate, and the portion of the adjacent fence that the gate covers in the open position Space or screen to prevent a 2 1/4 inch sphere from passing through. FSL700 Slide Gate Operator...
  • Page 5: Internal Entrapment Prevention

    2. The gate operator and the slide gate conjunction with a contact when the gate is in the open and sensor. close cycles 3. At the front end of the gate when the gate is in the close cycle. FSL700 Slide Gate Operator...
  • Page 6: Manual Release

    To manually release the gate operator remove the cover and locate the Power ON-OFF switch.  Turning the power OFF allows the gate to be moved manually.  Turning the power back ON will resume normal operation. FSL700 Swing Gate Operator...
  • Page 7: Ul325 Gate Operator Classification

    CONTACT SENSOR: External device such as a edge sensor used to provide entrapment prevention located where a risk of entrapment or obstruction exists such as the leading edge, trailing edge, and posts mounted inside and outside of the vehicular slide gate and motor. FSL700 Slide Gate Operator...
  • Page 8: Warning Sign Installation

    Select the proper gate operator for the installation. Consider the usage, capacity, gate size, gate weight, and needed features and safety accessories.  If proper safety guidelines can not be followed do not install the gate operator. FSL700 Slide Gate Operator...
  • Page 9: Gate Operator Specifications

    Maximum Gate Weight ............. 1000 lbs Maximum Gate Length .............. 40 Feet Primary Entrapment Protection ..........Inherent Current Sensor Secondary Entrapment Protection ..........Provisions for Non-Contact & Contact Sensors UL325 Class of Operation ............Class I, II, II, IV FSL700 Slide Gate Operator...
  • Page 10: Gate Operator Location

    The application requires the use of an additional idler allowing for a vehicle to damage the operator sprocket = added expense. more easily.  The chain runs across the length of the gate allowing visitors to see and possible tamper with it. FSL700 Slide Gate Operator...
  • Page 11: Concrete Pad Size & Location

    ONCRETE OCATION The FSL700 vehicular gate operator is designed to be mounted on a concrete pad. Select a location for the gate operator to be installed. For pad location and size: 1. Determine the location for the operator to be installed. (Front Mount v. Rear 24”...
  • Page 12: Gate Operator Bolt Down

    5. Tighten the chain using the chain bolts so the chain does not sag more than one (1) inch per 10 feet of travel. Do not over tighten! CORRECT ! WRONG ! GATE GATE GATE GATE OPERATOR OPERATOR CORRECT ! WRONG ! Approx. 11” FSL700 Slide Gate Operator...
  • Page 13: Chain Connection - Rear Mount

    10. Tighten the chain using the chain bolts so the chain does not sag more than one (1) inch per 10 feet of travel. Do not over tighten! WARNING: DO NOT INSTALL this product unless all safety standards are followed and all entrapment and pinch points have been eliminated. FSL700 Slide Gate Operator...
  • Page 14: Limit Switch Setup

    2. Standing inside the gate looking at the gate operator, determine if the gate opens to the LEFT or RIGHT. 3. If the gate opens to the LEFT, move DIP SWITCH 6 to the Left. 4. If the gate opens to the RIGHT, move DIP SWITCH 6 to the Right. Opens LEFT Opens Switch Switch FSL700 Slide Gate Operator...
  • Page 15: Lectrical Nstallation

    3. Connect the AC input wires to the AC terminal located on the bottom/center of the control box. See diagram below. 4. Batteries must be installed after the AC power is on. See Battery Power Connection. GREEN = Ground WHITE = Neutral BLACK = 120 VAC FSL700 Slide Gate Operator...
  • Page 16: Battery Power Connection

    Additional 24 VDC for accessories may be found on the Radio Terminal, Edge/Photo Terminal, and External Loop Terminal. A connection between 24V DC+ and Common will supply power. FSL700 Slide Gate Operator...
  • Page 17: Master/Slave Connection

    Master Slave Gate Operator Gate Operator Master Slave Switch 3: Switch 3: 24 VDC WIRED Connection [GND[ to [GND] BROWN [TX+] to [RX+] GREEN [TX–] to [RX–] GREEN-WHITE [RX+] to [TX+] ORANGE [RX–] to [TX–] ORANGE-WHITE FSL700 Slide Gate Operator...
  • Page 18: Ate Perator Djustments

    4. Only resetting the operator will reactivate the gate and return it to normal operation. 5. To reset the operator in a Hard Shut Down situation: Press the reset button on the left side of the controller or turn the power switch OFF and back ON. FSL700 Slide Gate Operator...
  • Page 19: Close Time Delay Adjustment

    If a closed gate is forced off limit, alarm sounds, motor stops open movement and closes gate. OFF: Normal Soft Start, Soft Stop mode. Hard Start Operator starts with 40% motor power for more starting torque. Normal start = 5% motor power. FSL700 Slide Gate Operator...
  • Page 20: Accessory Connections

    CCESSORY ONNECTIONS CCESSORY ONNECTIONS CCESSORY VERVIEW FIRE LOCK Card Access Phone Entry CLOSE Photo Cell Key Box OPEN STOP Photo Cell CLOSE Radio Receiver OPEN FSL700 Slide Gate Operator...
  • Page 21: Edge Sensor Connections

    Wireless contact sensors should be checked on a regular basis. Batteries should be replaced on a regular basis. Use only UL325 compliant devices and follow all installation guidelines set forth by the FSL700 Slide Gate Operator...
  • Page 22: Photo Sensor Connections

    For example, a photo beam will not cover the full height of a gate/fence area. Refer to the diagram below. CLOSE Use only UL325 compliant Photo Cell devices and follow all installation guidelines set forth by the manufacturer. FSL700 Slide Gate Operator...
  • Page 23: Standard Reverse Connections

    1. Allows external input to reset gate operator during a Hard Shutdown. External 2. Allows external input to reset operator settings during Reset installation. Connecting External Reset Devices: 1. Connect Reset Button to RESET and COMMON. FSL700 Slide Gate Operator...
  • Page 24: Access Control Connection

    This prevents the Fire Input from closing the gate if in the building codes and Fire Lock requirements. open position Connecting Access Devices: 1. Connect Fire Lock Control relays to FIRE and COMMON. (Most devices use Normally Closed & Common) FSL700 Slide Gate Operator...
  • Page 25: Radio Receiver Connections

    2. If the Radio Receiver uses 24VDC, connect Radio Power to RADIO PWR +24VDC and RADIO PWR - 24VDC. Connecting FAAC XR2 Radio Receivers: 1. Connect XR2 N.O. relay contacts to RADIO N.O. and RADIO COMMON. 2. Connect XR2 Power + to RADIO PWR +24VDC and XR2 Power - to RADIO PWR -24VDC.
  • Page 26: Alarm & Warning Light Connections

    2. Connect the Solar Panel positive to SOLAR + 3. Connect the Solar Panel negative to SOLAR - 12VDC, 20 Watt Batteries should be tested regularly for proper battery backup operation. Batteries should be replaced each year or as needed. FSL700 Slide Gate Operator...
  • Page 27: Basic Loop Layout

     Seal the loop slots with a sealant. Make sure the sealant is 21’ to 60’ able to sink to the bottom of the loop slot and completely encase the loop wire. The wire should not move when the 61’ to 240’ sealant has set. 241’ & Up FSL700 Slide Gate Operator...
  • Page 28: Plug-In Loop Detector Connections

    There are three plug-in terminals (Shadow, Reverse, Open) located on the gate controller. Detectors plugged into a specific socket will perform that function. To connect a PLD1500: Plug-In Loop Detector Inputs: 1. Shadow Loop: Not used on FSL700. 2. Reverse Loop: Plug detector into center socket. Make sure detector is secure and snapped in.
  • Page 29: Troubleshooting Tips

    3. Run a new CAT5 wire on top of the driveway to test the master slave communication. This will determine if the underground wire is good or bad. 4. Possible damage to the control board master slave components. Have boards repaired. FSL700 Slide Gate Operator...
  • Page 30: Spare Parts

    Controller PCB, heat sink and faceplate assembly GC3000 Controller Assembly (No PCB, faceplate) MOTOR-0500-24 Motor - 500W, 24VDC SL-0020 Gearbox 15:1 SL1000+ Limit stand assembly with switches 3540 Battery (single) SL-1001 Chain idler assembly SL-0002 Chain sprocket FSL700 Slide Gate Operator...
  • Page 31 PARE ARTS PARE ARTS FAAC p/n Description SL-0008 Limit nut guide SWITCH-0100 Limit switch AAA0450 Sensor cup assembly WIRE1101SK Sensors wire assembly with screws AAA-0402 Motor Adapter Plate FSL700 Slide Gate Operator...
  • Page 32: Imited Warranty

    FAAC FAAC International, Inc. to be free from defects in material International, Inc. The warranty herein above set forth shall...