  • Page 3: Fitting The Batteries

    The program is loaded into the nonvolatile memory of the 460P , where it can be subsequently modified, again using Before going on to describe the use of the FAACTOTUM, a few the FAACTOTUM. basic points should be made clear: The program can also be saved in the FAACTOTUM’s internal...
  • Page 4 CONNECTION TO AN EXTERNAL POWER PACK a program onto the card, to change the program already The FAACTOTUM (Fig. 3) has a socket for connection to an present or to perform diagnostics and check the functionality external power pack (not provided).
  • Page 5: Description Of The Keys

    ON/OFF background. Press this key to turn the FAACTOTUM on and off. When pressed together with the SHIFT key (see point 8) the Warning: if the programmer is turned off before the...
  • Page 6: Mode Selection

    FAACTOTUM memory, turn- state of the terminal block inputs. ing the FAACTOTUM off will result in the loss of entered data The conventional logics (Logics A, S, E, EP , P , B, C and B/C) are...
  • Page 7 ENTER, or key in the corresponding number directly. To load the program from the 460P , the FAACTOTUM must be connected to it using the appropriate cable. CONNECT TO 460 P - If the FAACTOTUM is already connected, press ENTER...
  • Page 8: Electric Locks

    (cont.) Using the GATECODER on the automation: USE GATECODER ? 1 = Use GATECODER 2 = Do not use GATECODER 1 YES 2 ->NO Make the selection by moving the arrow-shaped cursor alongside the desired option using the keys and pressing ENTER, or key in the corresponding number directly.
  • Page 9 LOGIC SELECTION This menu displays the currently used logic and provides the option of changing it LOGIC : XXXXXXXX by selecting one of the logics contained in the FAACTOTUM memory: 1-> CURRENT 1 = Maintain currently loaded logic STANDARD...
  • Page 10 ESC key, which takes you back to the beginning of the cycle. N.B.: 1) The time learning cycle is displayed only if the FAACTOTUM is connected to the 460P control unit. 2) The “DECELERATE” option in the cycle menus appears only if Gatecoder is used, or if deceleration by time is used.
  • Page 11 (cont.) When the key is pressed, Leaf 1 begins to open and the arrow on the display OPEN LEAF 1 moves alongside the “DECELERATION” option. OPEN When Leaf 1 has reached the position where you wish opening deceleration to DECELERATE begin, press the key again to save the position.
  • Page 12: Advanced Programming

    In particular, make changes only to the registers for which an explanation is given CONSULT in the instructions. INSTRUCTIONS Press ENTER to proceed, otherwise after about 7 seconds the FAACTOTUM will return automatically to the previous menu. Select the register for the parameter to be set. CHANGE REGISTER Enter the register number using the number keys.
  • Page 13 If you select an occupied location, saving will cause the resident logic to be overwritten. SAVING IN PROGRAMMING MEMORY It is now possible to save the program in the FAACTOTUM internal memory for future use. SAVE IN MEMORY? Select option:...
  • Page 14 For further information, read chapter 11 “Checking voltages”. To perform complete diagnostics on the automation, the FAACTOTUM must be CONNECT TO 460P connected to the 460P electronic control unit.
  • Page 15 - OK = The Failsafe has run correctly - KO = The Failsafe has found a fault With the FAACTOTUM connected to the card, it is possible to check the state of the automation according to the operation of the various activation devices under this menu.
  • Page 16: Special Functions

    ENTER, or key in the corresponding number directly. go to “PROGRAMMING” The FAACTOTUM is ready to transfer the contents of its memory when requested by PC CONNECTION the connected computer. Special software must be installed on the computer. The connection must be made using the special cable between the computer serial port (COM1 or COM2) and the FAACTOTUM serial connector (see fig.
  • Page 17: Voltage Check

    VOLTAGE CHECK Limitations in assigning of inputs: 1) Terminal IN1 (OPEN-A) does not appear in the assigning cycle The voltages on the 460P card tested by the FAACTOTUM are because it cannot be changed. protected from short-circuit by fuses: 2) Terminals IN2-IN5 can be assigned different functions to those Fuse F1 = transformer primary set by default, chosen among inputs 6-13 given in table 2.
  • Page 18: Setting Registers

    The registers are identified by a FAACTOTUM memor y. The other “System configuration number and consist of 8 bits each. registers” contain parameters which determine operation Each bit has a specific meaning and its setting (possible of the automation regardless of the type of logic.
  • Page 19 EXAMPLES OF REGISTER SETTINGS REG. No. VALUE FUNCTION DEFAULT The following are some examples of register settings for the most 14 * 1000XXXX timed courtesy contact 0000XXXX useful functions, complete with explanations. Default: standard warning light function The registers marked with an asterisk (*) are “Logic registers” (see chapter 13).
  • Page 20 Sets the duration of the opening/closing reversing stroke. The the Gatecoder anti-crushing safety or the “SAFE-CL ” safety. reversing stroke, which facilitates operation of the electric locks, is performed if set in the FAACTOTUM programming. REG. No. VALUE FUNCTION DEFAULT REG.