Page 1
DSL2000 Slide Gate Operator FAAC International Inc. FAAC International Inc. Headquarter & East Coast Operations West Coast Operations 5151 Sunbeam Road #9-11 357 S Acacia Avenue #357 Jacksonville, FL 32257 Fullerton, CA 92831 American Built (866) 925-3222 (800) 221-8278 www.FAACUSA.com...
Read and follow all U.L. and Safety Standards before installing any access device. Please refer to this manual and qualified personnel for assistance. DO NOT install this device unless all entrapment and pinch points are eliminated. DSL2000 Slide Gate Operator...
MUST be installed on all gates to avoid all potential hazards and entrapment. 9. SAVE THESE INSTRUCTIONS WARNING: DO NOT INSTALL this product unless all safety standards are followed and all entrapment and pinch points have been eliminated. DSL2000 Slide Gate Operator...
Page 4
Space or screen to prevent a 2 1/4 inch sphere from passing WARNING: DO NOT INSTALL this product unless all safety standards are followed and all entrapment and pinch points have been eliminated. DSL2000 Slide Gate Operator...
2. The gate operator and the slide gate when the gate protect areas in front of the adjacent fence. is in the open and close cycles gate. 3. At the front end of the gate when the gate is in the = Edge Sensor close cycle. DSL2000 Slide Gate Operator...
CONTACT SENSOR: External device such as a edge sensor used to provide entrapment prevention located where a risk of entrapment or obstruction exists such as the leading edge, trailing edge, and posts mounted inside and outside of the vehicular slide gate and motor. DSL2000 Slide Gate Operator...
Read and follow all U.L. and Safety Standards before installing any access device. Please refer to this manual and qualified personnel for assistance. DO NOT install this device unless all entrapment and pinch points are eliminated. DSL2000 Slide Gate Operator...
= added expense. The chain runs across the length of the gate allowing The application requires the use of an additional idler visitors to see and possible tamper with it. sprocket = added expense. DSL2000 Slide Gate Operator...
ONCRETE OCATION The DSL2000 vehicular gate operator is designed to be mounted on a concrete pad. Select a location for the gate operator to be installed. For pad location and size: 1. Determine the location for the operator to be installed. (Front Mount v. Rear Mount) 24”...
5. Tighten the chain using the chain bolts so the chain does not sag more than one (1) inch per 10 feet of travel. Do not over tighten! CORRECT ! WRONG ! GATE GATE GATE GATE OPERATOR OPERATOR CORRECT ! WRONG ! Approx. 11” DSL2000 Slide Gate Operator...
10. Tighten the chain using the chain bolts so the chain does not sag more than one (1) inch per 10 feet of travel. Do not over tighten! WARNING: DO NOT INSTALL this product unless all safety standards are followed and all entrapment and pinch points have been eliminated. DSL2000 Slide Gate Operator...
3. If the gate opens to the LEFT, move DIP SWITCH 6 to the Left. If the gate opens to the RIGHT, move DIP SWITCH 6 to the Right. Opens LEFT Opens RIGHT Switch 6: Switch 6: DSL2000 Slide Gate Operator...
3. Connect the AC input wires to the AC terminal located on the bottom/center of the control box. See diagram below. 4. Batteries must be installed after the AC power is on. See Battery Power Connection. GREEN = Ground WHITE = Neutral BLACK = 120 VAC DSL2000 Slide Gate Operator...
Additional 24 VDC for accessories may be found on the Radio Terminal, Edge/Photo Terminal, and External Loop Terminal. A connection between 24V DC+ and Common will supply power. DSL2000 Slide Gate Operator...
MASTER GREEN to SLAVE GREEN (Pin 6 to Pin 1) MASTER BROWN WHITE to SLAVE BROWN WHITE (Pin 5 to Pin 5) Slave Gate Operator Slave Plug Slave Switch 3: Master Master Plug Gate Operator Master Switch 3: DSL2000 Slide Gate Operator...
5. To reset the operator in a Hard Shut Down situation: Press the reset button on the left side of the controller or turn the power switch OFF and back ON. WARNING: DO NOT INSTALL this product unless all safety standards are followed and all entrapment and pinch points have been eliminated. DSL2000 Slide Gate Operator...
When closed, if gate is forced off limit, alarm sounds, motor stops open movement and closes gate. OFF: Gate opens and closes normal. Hard Start Gate starts with 40% motor power for more starting torque. Normal start = 5% motor power. DSL2000 Slide Gate Operator...
Phone Entry CLOSE Photo Cell Key Box OPEN STOP Photo Cell CLOSE Radio Receiver OPEN WARNING: DO NOT INSTALL this product unless all safety standards are followed and all entrapment and pinch points have been eliminated. DSL2000 Slide Gate Operator...
Wireless contact sensors should be checked on a regular basis. Batteries should be replaced on a WARNING: DO NOT INSTALL this product unless all safety standards are followed and all entrapment and pinch points have been eliminated. DSL2000 Slide Gate Operator...
Use only UL325 compliant devices and follow all installation guidelines set forth by the manufacturer. WARNING: DO NOT INSTALL this product unless all safety standards are followed and all entrapment and pinch points have been eliminated. DSL2000 Slide Gate Operator...
1. Allows external input to reset gate operator during a Hard Shutdown. External 2. Allows external input to reset operator settings during Reset installation. Connecting External Reset Devices: 1. Connect Reset Button to RESET and COMMON. DSL2000 Slide Gate Operator...
Fire Input from closing the gate if in the open position. NOTE: Consult your local Fire Department for proper building codes and Fire Lock requirements. Connecting Access Devices: 1. Connect Fire Lock Control relays to FIRE and COMMON. (Most devices use Normally Closed & Common) DSL2000 Slide Gate Operator...
1. Set DIP Switch 10 to ON for a 2 second delay on open. 2. Connect Solenoids to SOLENOID NO and SOLENOID COM. 3. Connect Maglocks to MAGLOCK NC and MAGLOCK COM. Lock Power Switch 10: Solenoid Lock Power DSL2000 Slide Gate Operator...
2. Connect the Solar Panel positive to SOLAR + 3. Connect the Solar Panel negative to SOLAR - 12VDC, 20 Watt Batteries should be tested regularly for proper battery backup operation. Batteries should be replaced each year or as needed. DSL2000 Slide Gate Operator...
Seal the loop slots with a sealant. Make sure the sealant is 21’ to 60’ able to sink to the bottom of the loop slot and completely encase the loop wire. The wire should not move when the 61’ to 240’ sealant has set. 241’ & Up DSL2000 Slide Gate Operator...
There are three plug-in terminals (Shadow, Reverse, Open) located on the gate controller. Detectors plugged into a specific socket will perform that function. To connect a PLD1500: Plug-In Loop Detector Inputs: 1. Shadow Loop: Not used on DSL2000. 2. Reverse Loop: Plug detector into center socket. Make sure detector is secure and snapped in.
4. Run a new CAT5 wire on top of the driveway to test the master slave communication. This will determine if the underground wire is good or bad. 5. Possible damage to the control board master slave components. Have boards repaired. DSL2000 Slide Gate Operator...
Page 28
You MUST read, understand and agree with ALL items in this limited warranty! FAAC warrants this product to be free of defects in workmanship and materials for a period of (5) five years from the date of purchase. FAAC reserves the right of final determination to the cause of any defect or failure. FAAC shall, at its option, either repair or replace this product if returned freight prepaid to FAAC during the warranty period.