Diagnostics – Parking Light Flash Table
Flashes
• Doors locked, Starter Kill armed.
• End of Run Time.
TRUNK
1
• Start signal received by the Remote Car Starter.
• Cold Weather Mode cancelled.
• Cannot start after maximum number of attempts is reached.
• Doors unlocked, Starter Kill disarmed.
• Remote start attempt cancelled by remote.
2
• Exiting remote valet
• Exiting ignition valet
• Entering Cold Weather Mode.
• Entering or Exiting Ready Mode.
• Entering Extended Run Time.
3
• Entering remote valet
• Entering ignition valet
• +12 V where detected on the brake line and cranking was cancelled.
4
• Entering Tach-programming Mode
• New Transmitter programmed.
5
• Tach programmed.
• A remote start was attempted while a Tach or a vacuum signal was detected
6
before cranking.
• Unit reset: occurs when the Unit is reset to the factory defaults.
8
• The Hood Switch line went to ground during cranking or Run Time.
10
• There was an attempt to start the vehicle while the Remote Car Starter was
1 – pause – 2
in Valet Mode.
• There was an attempt to start the vehicle while the Remote Car Starter was
2 – pause – 2
in Home Valet Mode.
• The vehicle went out of Ready Mode: +12 V detected on the Brake Line.
4 – pause – 3
10 – pause – 3 • The vehicle went out of Ready Mode: the Hood Pin-switch went to ground.
• The Hood is up and the Hood Switch line went to ground. This is step one of
ON 2 sec.
the Programming Centre procedure.
• First press of the
ON 3 sec.
• Locking or unlocking a Door (with Door pulses configured to 4 sec.)
ON 4 sec.
• The Hood Pin-switch has been pressed twice: the Unit went into step 1 of the
Programming Centre procedure, and no Transmitter activity was detected for
20 seconds.
ON 25 sec.
• Or the Unit went into step 1 of the Transmitter Programming procedure and
no activity was detected for a few seconds. The Unit has exited the
Transmitter Programming procedure.
• If the unit gives irregular signals (1 to 10 flashes followed by a pause,
Irregular
followed by further flashes), the system is playing back Start Failure Codes.
This occurs when the Hood Pin-switch is pressed three times.
Constant
• Panic Mode was triggered.
flashes
up to 30 sec.
AS-2360TW User Guide
button pressed
button under Safe Start.
START
Description