Omron E5AN Communications Manual page 105

Digital temperature controllers
Hide thumbs Also See for E5AN:
Table of Contents

Advertisement

Address
Four-
Two-
Parameter name
byte
byte
mode
mode
010E
2107
Alarm Value 2
0110
2108
Alarm Value Upper Limit 2
0112
2109
Alarm Value Lower Limit 2
0404
2402
PV
0406
2403
Internal Set Point (See note 1.)
0408
2404
Multi-SP Monitor
040C
2406
Status (See notes 1 and 2.)
040E
2407
Status (See note 3.)
0410
2408
Status 2 (See notes 1 and 2.)
0412
2409
Status 2 (See notes 1 and 3.)
0420
2410
Decimal Point Monitor
0422
2411
Control Output 1 ON/OFF
Count Monitor
0424
2412
Control Output 2 ON/OFF
Count Monitor
0500
2500
Operation/Adjustment Protect
0502
2501
Initial Setting/Communications
Protect
0504
2502
Setting Change Protect
0506
2503
PF Key Protect
0508
2504
Move to Protect Level
050A
2505
Password to Move to Protect
Level
050C
2506
Parameter Mask Enable
Note 1: Not displayed on the Controller display.
Note 2: In 2-byte mode, the rightmost 16 bits are read.
Note 3: In 2-byte mode, the leftmost 16 bits are read.
6.1 Variable Area (Setting Range) List
Setting (monitor) value
H'FFFFF831 to H'0000270F (−1999 to 9999)
H'FFFFF831 to H'0000270F (−1999 to 9999)
H'FFFFF831 to H'0000270F (−1999 to 9999)
Temperature: Use the specified range for each sensor.
Analog: Scaling lower limit − 5% FS to Scaling upper limit +
5% FS
SP lower limit to SP upper limit
H'00000000 to H'00000003 (0 to 3)
See the 6.2 Status and status 2 for details.
See the 6.2 Status and status 2 for details.
See the 6.2 Status and status 2 for details.
See the 6.2 Status and status 2 for details.
H'00000000 to H'00000003 (0 to 3)
H'00000000 to H'0000270F (0 to 9999)
H'00000000 to H'0000270F (0 to 9999)
H'00000000 (0):
No restrictions in operation and adjust-
ment levels
H'00000001 (1):
Move to adjustment level is prohibited.
H'00000002 (2):
Display and change of only "PV" and
"PV/SP" parameters is allowed.
H'00000003 (3):
Display of only "PV" and "PV/SP"
parameters is allowed.
H'00000000 (0):
Move to initial setting/communications
setting level is allowed. (Move to
advanced function setting level is dis-
played.)
H'00000001 (1):
Move to initial setting/communications
setting level is allowed. (Move to
advanced function setting level is not
displayed.)
H'00000002 (2):
Move to initial setting/communications
setting level is prohibited.
H'00000000 (0):
OFF (Changing of setup on controller
display is allowed.)
H'00000001 (1):
ON (Changing of setup on controller
display is prohibited.)
H'00000000 (0): OFF
H'00000001 (1): ON
H'FFFFF831 to H'0000270F (−1999 to 9999)
H'FFFFF831 to H'0000270F (−1999 to 9999)
(Can only be set. The monitor value is always H'00000000.)
H'00000000 (0): OFF
H'00000001 (1): ON
Level
Operation
Advanced
function
setting
Protect
6-3