  • Page 1 ECo8x Ness ECO8x AlARm CONtROl pANEl InstallatIon & programmIng manUal Revision 1.5 A$15.00...
  • Page 2 “Australia’s largest Head Office: Ness Security Products Pty Ltd designer and ABN 28 069 984 372 Ph +61 2 8825 9222 Fax +61 2 9674 2520 manufacturer of ness@ness.com.au high quality security Ph 02 8825 9222 Fax 02 9674 2520 products”...
  • Page 3: Table Of Contents

    INstAllER FUNCtIONs send test report ..................46 siren test / panel reset /display software version RAdIO OptIONs ..................47 signal strength test, Ness Radio Interface connection RAdIO dEvICE pROgRAmmINg ............48 RAdIO KEy pROgRAmmINg ..............49 Real time Clock options .................50 mONItORINg OpERAtION monitoring operation, Contact Id codes ..........52...
  • Page 4: Installation Notes

    (Electrostatic discharge). 7. Wire to the circuit board terminal blocks, as per the wiring Once properly installed, Ness control panels are instructions shown in this installation manual. well protected from Esd. However, take note of the following precautions during installation.
  • Page 5: Input And Output Descriptions

    Ness ECO8x requires an AC transformer rating of 1.4 Amps A maximum of 2 x 1 Watt strobes (Ness part No. NOI300) can @ 17 v AC minimum. (Ness part No. 840-029 or pOW215) be connected to this output.
  • Page 6: Connection Diagram / Devices Wiring

    ECo8x ConnECtIon DIagram NOTICE Adsl broadband can interfere with the operation of your alarm dialler. It is recommended that a quality Adsl filter be installed as per the filter manufacturer's guidelines. Use Ness Adsl Filters 100-006 or 100-009. eCO8 – I ONtrOl...
  • Page 7 (all models) as 24hr SIREN WIRING EXAMPLE 5 EXTERNAL INTERNAL NESS ECO8x 100-238 Top Hat 12V Piezo Screamer N.O TAMPER SWITCH 100-172 Ness 12V Internal Siren 100-004 Flush Piezo Screamer (761-002) Colour: BLACK HORN SPEAKER (NOI110) BLACK The terminal block should...
  • Page 8: Keypad

    New alarm/s in MEMORy selected. memory. Red Illuminated button Normal. Zone/s are the Ness ECO8x keypad provides EXCLUDE Excluded. important visual and audible indication Red Illuminated button of the system status and is the main Normal. User program...
  • Page 9: Operation

    opEratIon sUmmary OpERAtION by KEyPAD by RADIO KEy to ARM press the panel must initially be disarmed. (If the Arming shortcut is enabled, p62E 5E) or press press the ON button once. or press (If Code Only Arming has been enabled for that user code.
  • Page 10: Quick Start Programming

    I n g QUICK start programmIng Use one of these programming summaries for fast setup of your Ness ECO8x control panel as a local, Audible monitored or Central station monitored system. QUICK START 1...
  • Page 11: How To Enter Program Mode

    p r o g r a m m I n g program moDE lEvEls FACTORy DEFAULTS tAblE 4. FlOW CHARt master Code: 123 Installer Code: 000000 Power up with Program Link OFF (Usually on first time installation) INSTALLER PROGRAM Mode INSTALLER PROGRAM MODE Installer program mode allows PROGRAM LIGHT IS FLASHING...
  • Page 12: User Codes

    UsEr CoDEs P11E – P2E the ECO8x control panel has 15 User Codes which are used to operate the panel by a variety of methods – each User Code can be assigned to either a KEypAd COdE or a PROGRAM MODE LEVEL RAdIO KEy.
  • Page 13: Programming User Codes

    If in Home mode, then the action is to exit Home mode. E RAdIO COdE. Enables selected user codes as Radio Codes for operation by Ness Radio Key or Radio Keypad. (page 49 - how to program Radio Codes). eCO8 –...
  • Page 14: Timers

    p r o g r a m m I n g Option No. description default Note p26E ENtRy dElAy tImE seconds p28E EXIt dElAy tImE seconds p29E sIREN REsEt tImE minutes P2E Entry DElay tImE the Entry delay time is the time given to disarm the panel after an Entry delay zone is PROGRAM MODE LEVEL triggered.
  • Page 15: Vibration Sensitivity

    1 second ZONEs p38E 3 second ZONEs * Extreme sensitivity (p31E) should not be used. It is provided as a guide only Ness NEssENsOR vibration sensor ™ part No. vIb100 AdJUstINg NEssENsORs In addition to zone sensitivity adjustment, the overall sensitivity of the Nesssensor can be Nessensors are sensitive to high adjusted by rotating the body of the Nesssensor within its bracket.
  • Page 16 p r o g r a m m I n g ZONEs Option No. description p39E dOUblE tRIggER zones ZONE dElAy typEs p40E INstANt zones ON ON ON ON ON ON Only one option per zone can be selected. p41E ENtRy dElAy 1 zones For example, a zone cannot be instant and p42E...
  • Page 17: Area Mapping

    p r o g r a m m I n g HanDovEr ZonEs P42E Handover zones are delayed only if entry is made through an Entry delay zone first. PROGRAM MODE LEVEL If a Handover zone is triggered first, the zone behaves as an instant zone. Normally, Installer, Remote by pC.
  • Page 18: Definitions. Day Zones, Temp Day Zones, Home

    p r o g r a m m I n g arEa partItIonIng arEa partItIonIng HomE moDE & HomE moDE Home mode allows selected zones to be armed DEFINITION whilst the system is disarmed. For example, this the panel can be armed in HOmE mode Area partitioning allows the control panel is often used to arm door and windows sensors if Area2 is already armed on these condi-...
  • Page 19 p r o g r a m m I n g P1E HomE moDE ZonEs Home mode zones allow you to Arm selected zones while others are ignored. typically PROGRAM MODE LEVEL used for perimeter zones such as windows and doors while you are at home. Installer, Remote by pC.
  • Page 20: Zone To Output Mapping

    p r o g r a m m I n g ZonE to oUtpUt mappIng When a zone alarms, it can turn on any or all of these outputs: Sonalert, Strobe, Siren, Reset, AUX2. The programming is selected with options P4E – PE. Simply set the zone number to the output to select it.
  • Page 21 p r o g r a m m I n g sIrEn oUtpUt ZonEs PE selects the zones to trigger the siren output. PROGRAM MODE LEVEL Installer, Remote by pC. PROGRAMMING SEQUENCE: P57E [Zone No]E toggles the options ON and OFF FACTORy DEFAULT All ON.
  • Page 22: Various Options

    KEysWItCH opEratIon P0E 3E An externally fitted, normally open momentary Keyswitch can be used to Arm and disarm the ECO8x. PROGRAM MODE LEVEL Installer, Remote by pC. the keyswitch is wired to zone 8 (zone 8 is then no longer available as a normal alarm input, but is still available for use as a Radio Zone).
  • Page 23 p r o g r a m m I n g tampEr sIrEn loCKoUt P0E 4E this option programs the tamper input to lockout, i.e. cause the siren & Reset outputs PROGRAM MODE LEVEL to sound only once whilst the panel is armed. Installer, Remote by pC.
  • Page 24: Tamper/Keypad Panic Output Mapping

    p r o g r a m m I n g 1E 2E 3E 4E E E E 8E Option No. description p61E ON ON ON ON ON ON ON ON tAmpER & pANIC AlARm mAppINg P1E 1E–4E tampEr alarm / oUtpUt mappIng this option selects which outputs will trigger when a tamper Alarm occurs.
  • Page 25: System Operation Shortcuts

    p r o g r a m m I n g 1E 2E 3E 4E E E E 8E Option No. description p62E ON ON ON OpERAtION sHORtCUts EtC P2E 1E–E systEm opEratIon sHortCUts some keypad operations can be programmed to operate with or without a User Code. PROGRAM MODE LEVEL Installer, Remote by pC.
  • Page 26: Home Mode Output Mapping

    p r o g r a m m I n g 1E 2E 3E 4E E E E 8E Option No. description p63E ON ON ON ON HOmE mOdE & dAy mOdE mAppINg HomE moDE oUtpUt mappIng P3E 1E–4E this option selects which outputs are triggered by alarms in Home mode. PROGRAM MODE LEVEL Installer, Remote by pC.
  • Page 27: Miscellaneous Options

    p r o g r a m m I n g 1E 2E 3E 4E E E E 8E Option No. description p64E ON ON mIsC. OptIONs P4E 1E brIEf HomE moDE alarm Alarms in Home mode can either activate the programmed outputs for siren time PROGRAM MODE LEVEL duration (p29E) or they can activate the outputs for 2 seconds only.
  • Page 28: Keypad Fire Alarm

    p r o g r a m m I n g P4E E 50Hz maIns frEQUEnCy selects either 50Hz or 60Hz mains power frequency operation. the factory default of PROGRAM MODE LEVEL 50Hz is for use in Australia and New Zealand. Users in North America should select Installer, Remote by pC.
  • Page 29: Aux1 Output Options

    p r o g r a m m I n g AUX1 Output on the main terminal strip 1E 2E 3E 4E E E E 8E Option No. description p65E AUX1 OUtpUt OptIONs select one output type for AUX1. PE 1E aUX1 oUtpUt = smoKE DEtECtor poWEr When this option is enabled the AUX1 output can be used to provide power for latching PROGRAM MODE LEVEL...
  • Page 30: Aux2 Output Options

    p r o g r a m m I n g AUX2 Output is on header J3 on the main board 1E 2E 3E 4E E E E 8E Option No. description p66E AUX2 OUtpUt OptIONs select one output type for AUX2. PE 1E aUX2 oUtpUt = ZonE alarm When this option is on, zones selected in p59E will turn on AUX2 when they go into...
  • Page 31 p r o g r a m m I n g PE E aUX2 oUtpUt = faIl to CommUnICatE oUtpUt When this option is enabled AUX2 will turn on at the start of the fourth dialout attempt. PROGRAM MODE LEVEL this can be used as Fail to Communicate output to trigger backup communications Installer, Remote by pC.
  • Page 32: Misc. Options

    p r o g r a m m I n g 1E 2E 3E 4E E E E 8E Option No. description p69E mIsC. OptIONs 2 PE 1E arm1 pUlsE oUtpUt ARm1 Output will pulse on for 2 seconds whenever Area1 is armed. (disarming does PROGRAM MODE LEVEL not pulse the output).
  • Page 33 HomE arm by raDIo KEy aUX bUtton PE 8E this option enables the AUX button on a Ness RK4 Radio Key to arm Home mode. PROGRAM MODE LEVEL (this option is independent of p69E 5E, Home mode arming by radio key ON/OFF Installer, Remote by pC.
  • Page 34: Telephone Numbers

    p r o g r a m m I n g Option No. description default p70E tElEpHONE NUmbER 1 - pRImARy p71E tElEpHONE NUmbER 2 - sECONdARy p81E tElEpHONE NUmbER - CAllbACK FOR UplOAd p72E ClIENt ACCOUNt NUmbER 0000 tElEpHonE nUmbErs 1 & 2 P0E, P1E the panel can dial up to 2 phone numbers when an event is to be transmitted to a PROGRAM MODE LEVEL...
  • Page 35: Account Numbers

    CLIENT CODE NOTES dialler client codes can now be entered in Hexadecimal. Use the following keys Note 1: the ECO8x keypad does not to enter the hex digits b, C, d, E or F. display the Hex digits. A test report...
  • Page 36: Alarm Reporting Options

    p r o g r a m m I n g ZONEs 1 2 3 4    8 Option No. description p74E REpORt ZONE AlARms ON ON ON ON ON ON ON ON p76E REpORt ZONE REstORAls ON ON ON ON ON ON ON ON mUltIplE ZONE AlARms p78E P4E...
  • Page 37: Report Miscellaneous Alarms

    p r o g r a m m I n g AlARm REstORAl Option No. Option No. dEFAUlt dEFAUlt PE, P2E duress p75E p77E REPORT MISCELLANEOUS medical p75E p77E ALARMS Kp panic & Ks panic p75E p77E PROGRAM MODE LEVEL Fire p75E p77E...
  • Page 38: Test Call Options

    p r o g r a m m I n g Option No. description default Note p83E tEst CAll INtERvAl x2 = 168hrs p84E tImE bEFORE FIRst tEst CAll x2 = 12hrs P83E tEst Call IntErval test calls to the Central station can be sent at intervals between 2 and 198 hours in 2 PROGRAM MODE LEVEL hour increments.
  • Page 39: Dialler Format Options

    p r o g r a m m I n g 1E 2E 3E 4E E E E 8E Option No. description p86E REpORtINg FORmAts P8E 1E DIsablE DIallEr this option disables the dialler even if telephone numbers and other dialler options are PROGRAM MODE LEVEL programmed.
  • Page 40 p r o g r a m m I n g 1E 2E 3E 4E E E E 8E Option No. description p87E mIsC. dIAllINg OptIONs P8E 1E splIt DIal prImary/sEConDary pHonE nUmbErs this option selects the order in which telephone numbers 1 & 2 are dialled. PROGRAM MODE LEVEL Installer, Remote by pC.
  • Page 41: Forced Opening Report

    p r o g r a m m I n g 1E 2E 3E 4E E E E 8E Option No. description p88E ON ON OpEN/ClOsE REpORtINg OptIONs arEa1 opEn/ClosE rEports P88E 1E Enables or disables sending of AREA1 Open/Close reports. the User Id of the code PROGRAM MODE LEVEL used is included in the report.
  • Page 42: Enable Test Calls

    p r o g r a m m I n g 1E 2E 3E 4E E E E 8E Option No. description p89E ON ON ON ON mIsC. REpORtINg OptIONs EnablE tEst Calls P8E 1E this option enables the reporting of dialler test calls to the Central station. PROGRAM MODE LEVEL Installer, Remote by pC.
  • Page 43: Swinger Shutdown

    p r o g r a m m I n g P8E 4E sWIngEr sHUtDoWn limits the number of calls made by a zone alarm in any one armed period. PROGRAM MODE LEVEL Alarm reports are normally limited to 15 multiple reports per zone. Installer, Remote by pC.
  • Page 44: Remote Access

    p r o g r a m m I n g 1E 2E 3E 4E E E E 8E Option No. description p90E UplOAd/dOWNlOAd OptIONs rEmotE aCCEss P0E 1E When selected On, this option allows the panel to be remotely upload/downloaded by PROGRAM MODE LEVEL a remote computer or controlled by a remote telephone.
  • Page 45: Reset Factory Defaults

    p r o g r a m m I n g Option No. description these options allow selective restoring p95E ClEAR RAdIO dEvICEs of various factory defaults. For example, you can default (clear) all the User p96E ClEAR mEmORy Codes, without affecting any other p97E ClEAR pANEl OptIONs (REstORE FACtORy dEFAUlts) programmed options.
  • Page 46: Special Installer Functions

    Example, version 1.0 ECO8x is displayed by flashing 1 0 followed by 0 2. (the model number for the ECO8x is 02.) this test operates in User and Installer program mode.
  • Page 47: Radio Options

    • In cases where the receiver needs to be located closer to the transmitters, the Ness Radio low battery generates HIstORy and dIAllER Interface can be installed up to 50 metres away from the control panel.
  • Page 48: Radio Device Programming

    • Radio devices can only be deleted by raDIo DEvICE programmIng keypad. Each of the zones of the ECO8x can be a radio zone. Once programmed, zones can • some Ness Radio devices send accept both radio devices and normal zone inputs simultaneously.
  • Page 49: Radio Key Programming

    Each of the 15 User Codes, except for the master Code, can be programmed to be in the case of a lost Radio Key. a Radio Codes. this allows up to 14 Ness Radio Keys to be used for Arming and • Radio Keys are assigned to User disarming of the panel.
  • Page 50: Real Time Clock Options

    p r o g r a m m I n g Option No. description default Note p130E REAl tImE ClOCK sEt MINUTES 00–59 minutes p131E 00–23 hours REAl tImE ClOCK sEt hOURS (00=midnight) p132E REAl tImE ClOCK sEt DAy 01–31 days p133E REAl tImE ClOCK sEt MONTh 01–12 months...
  • Page 51 InstallEr's notEs eCO8 – I ONtrOl aNel NstallatION aNual...
  • Page 52: Monitoring Operation Monitoring Operation, Contact Id Codes

    CEntral statIon monItorIng CENTRAL STATION MONITORING the Ness ECO8x control panel has an on-board digital dialler which can send detailed alarm messages to a central monitoring station. MONITORING the digital messages can include information about the zone/s which caused the...
  • Page 53: Audible Monitoring

    aUDIblE monItorIng AUDIBLE MONITORING While Central station monitoring is recommended, the panel can also send audible alarm reports to any dtmF capable telephone. the types of alarms sent are listed in the Reporting Format table. MONITORED TELEPHONE LINE ANY TELEPHONE the basic audible message consists of the warning words AlARm, AlARm, AlARm PREMISES followed by the alarm message sent as a series of beeps:...
  • Page 54: Programming Options Summary

    ECo8x optIons sUmmary page 1 of 2 dEsCRIptION OPTION DEFAULT PAGE PROGRAMMING USER CODES pIN programming and EXtRA OptIONs for each user code. P2E ENtRy dElAy time 20 sec EXTRA OPTIONS P28E EXIt dElAy time 60 sec EXClUdE+E toggles EXtRA OptIONs...
  • Page 55 ECo8x optIons sUmmary page 2 of 2 dEsCRIptION dEsCRIptION OPTION OPTION DEFAULT PAGE DEFAULT PAGE P3E P82E Home mode alarms to REsEt output send REstORAl report immediately Home mode alarms to stRObE send REstORAl after siren time send REstORAl after disarm & seal...
  • Page 56: Specifications And Approvals

    Ness. Ness reserves the right to make changes to features and specifications at any time without prior notification in the interest of ongoing product development and improvement.