System Control System Adjustment; Initialization Of D, E, F; Battery End Adjustment (Vc-195 Board) - Sony Handycam CCD-TRV3E Service Manual

Video camera recorder
Hide thumbs Also See for Handycam CCD-TRV3E:
Table of Contents

Advertisement

3-2.

SYSTEM CONTROL SYSTEM ADJUSTMENT

1. Initialization of D, E, F Page Data
If the D, E, F page data is erased due to some reason, perform "1-2.
INITIALIZATION OF D, E, F PAGE DATA", of "5-1. CAMERA
SECTION ADJUSTMENT".

2. Battery End Adjustment (VC-195 board)

Set the battery end voltage.
If the voltage is incorrect, the life of the battery will shorten.
The image at the battery end will also be rough.
Mode
Camera recording
Subject
Arbitrary
Measurement Point
LCD display of the adjusting remote
Measuring Instrument commander
Adjustment Page
D
Adjustment Address
30 to 34
Note 1: The lens block and cabinet (R) must be connected.
Switch setting
1) AUTO FOCUS ............................. OFF
2) LCD screen ................................... Closed
3) NIGHT SHOT .............................. OFF
(NIGHT SHOT model)
Connection:
1) Connect the regulated power supply and the digital voltmeter
to the battery terminal as shown in Fig. 5-3-4.
Adjusting method:
1) Adjust the output voltage of the regulated power supply so that
the digital voltmeter display is 6.1±0.1Vdc.
2) Turn off the power supply.
3) Turn on the HOLD switch of the adjusting remote commander.
4) Turn on the power supply.
5) Load a cassette, and set to the camera recording mode.
6) Select page: 0, address: 01, and set data: 01.
7) Decrease the output voltage of the regulated power supply so
that the digital voltmeter display is 5.30±0.01Vdc.
8) Select page: 3, address: 5D, read the data, and this data is named
Dref.
9) Select page: D, address: 30, set data: Dref, and then press the
PAUSE button of the adjusting remote commander.
10) Convert Dref to decimal notation, and obtain Dref '. (Refer to
Table 5-1-2. "Hexadecimal-decimal conversion table")
11) Calculate D
', D
', D
' and D
31
32
33
(decimal calculation), convert it to a hexadecimal number, and
input each adjustment address.
Address: 31
D
Address: 32
D
Address: 33
D
Address: 34
D
Note 3: After setting each data, be sure to press the PAUSE button.
' using following equations
34
' = Dref ' + 5
31
' = Dref ' + 32
32
' = Dref ' + 53
33
' = Dref ' + 64
34
12) Select page: 0, address: 01, and set data: 00.
5-42
Fig. 5-3-4.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents