Low Output-Volt
Output voltage is lower
than the selected cells
or voltages.
Pls select proper cells
or voltages.
High Output-Volt
Output voltage is higher
than the selected cells
or voltages.
Pls select proper cells
or voltages.
Temp. Sensor
A temperature sensor is
connected in reverse or
is defective.
Bat.Temp Too Low
Battery temp is too low
to be operated !
Bat.Temp Too High
Battery temp is too high
to be operated !
Internal Temp.
Internal temp is too hot!
Contact Hobby Services
if this message appears
often.
BLC Volt High
Balancer cell voltage is
too high !
Over cell is [0]
41
◆ A Low Output-Volt error message indicates that
either the voltage setup is below the requirements for
the charging/discharging battery or the number of cells
has been improperly selected.
◆ A High Output-Volt error message indicates that
either the out voltage setup exceeds the requirements
for the charging/discharging battery or the number of
cells has been improperly selected.
◆ A Temp. Sensor error message indicates that the
temperature sensor either is plugged in "backwards"
with the positive to negative connections inverted or
has a fault inside the sensor.
◆ A Bat. Temp Too Low error message indicates that
the battery temperature is too low to operate using the
charging process.
◆ A Bat. Temp Too High error message indicates
that the he battery temperature exceeds the preset
temperature values.
◆ An Internal Temp. error message indicates that
the internal temperature within the charger ex-
ceeds the recommended operating conditions.
◆ A BLC Volt High error message indicates that
the balancer cell voltage exceeds the recom-
mended operating conditions.
BLC Volt Low
Balancer cell voltage is
too low !
Low cell is [0]
Calibration
Either calibration data or
internal circuit might
have been damaged.
No Sensor
A temp-sensor is not
connected to the port.
Pls connect the sensor
to the port then restart!
Connection
Selected cells and
cells connected to the
balancing port are
different !
Pls recheck and restart!
Motor Current
Pls reconnect the moto
rand restart !
Balancer Port
BLC Port is opened.
Pls check the BLC port.
Sync. Command
Sync order failed.
Error occured in the
counterpart channel !
◆ A BLC Volt Low error message indicates that
the balancer cell voltage is below the recom-
mended operating conditions.
◆ A Calibration error message indicates that threre
is a fault in either the default calibration data or the
internal circuits of the charger.
◆ A No Sensor error message indicates that
the temperature sensor has been disconnected.
◆ A Connection error message indicates that the
preset number of cells and the detected number of
cells are different.
◆ A Motor Current error message indicates that
the operating current exceeds the value in the
MISC MOTOR function.
◆ A Balancer Port error message indicates that
the balance connector has been disconnected.
◆ A Sync. Command error message indicates that
the preset number of cells and the number of cells
of CH1, CH2 are not matched to the values entered
into the Charge/discharge and Sync modes,