Resource Upgrade; Blc Port Test; Slave Board Upgrade (Product Update); Error Messages - GRAUPNER Polaron Operating Instructions Manual

2 channels ac/dc charger
Hide thumbs Also See for Polaron:
Table of Contents

Advertisement

Resource Upgrade (Image and sound download)

RESOURCE UPGRADE

<Image & Sound>
Press the button.
'Download Start '
< WARNING !!! >
DO NOT TURN OFF
THW POWER.
Smart BMS *POLARON*
1. This screen is used to downlowed image and sound files from a PC to the flash memory in the
charger.
2. Program updates are found at www.openhobby.com and www.graupner-sj.com
BLC Port Test (Checking balance port)
*** BLC Port T est ***
This screen (left) is used to check the balance port. Please note
Testing BLC Port...
that the user cannot access this mode. (Only available to the
manufacturer)
Smart BMS *POLARON*

◎ SLAVE BOARD UPGRADE (Product Update)

1. This screen (left) is for product updates from a PC
(personal computer).
2. Updates are available at www.openhobby.com and
www.graupner-sj.com
39

◎ ERROR MESSAGES

POLARON AC/DC chargers have a number of error and
warning messages that are designed to advise the user
of any problems. Tapping the error message can clear the
message and return to the previous page.
▶ Input voltages of less than 11V or exceeding 15V.
No Battery
Battery is not connected
to the output.
Pls connect the battery to
the output then restart!
Reverse Polarity
A Battery is connected
to the output in reverse!
Pls correctly connect the
battery to the output.
Open Circuit
A Battery is disconnec-
ted during an operation.
Pls reconnect the battery
and restart!
Short-Circuited
Output short-circuited.
Pls check the output.
◆ A No Battery error message indicates that there is
no battery connected to the charger.
◆ A Reverse Polarity error message indicates that
the battery is plugged in "backwards", inverting
the positive to negative connections.
◆ An Open Circuit error message indicates that the
charging/discharging battery has been disconnected.
during an operation.
◆ A Short-Circuited error message may indicate
multiple errors, including faults at the charger output
leads, at the battery leads, within the battery and lo-
cations on the cables, causing the short circuit.
40

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Polaron s2002

Table of Contents