Charge mode selection in cycle mode
Discharge mode selection in cycle mode
The charge mode and the start delay time parameters are programmed.
Tap the box to activate (blue). Tap the DEC/INC button to select the
desired mode. Discharge modes are explained below
After counting down, the charger initiates the discharge process.
Tapping the Enter button
immediately initiate the
Start delay time
The start delay time can be set at values betwee 1-150 min-
utes. After the preset delay time has completed, the charger
initiates the cycle charge/discharge.

Cycle operation mode per battery type

Cycle charge discharge mode of the POLARON AC/DC Charger
LiPo, LiIon, LiFe, Pb
CC-CV
NORMAL
LINEAR
NiCd, NiMH
AUTO
NORMAL
LINEAR
This page (left) shows the battery check process after a con-
nection to the balancer has been established. The next page
is accessed
automatically. Tapping the Enter button
the charger to immediately initiate the
process.
Battery Cell Checking
25
will cause the charger to
charging process.
: Normal charge/discharge mode
: Normal charge/discharge mode
: The preset current is maintained throughout the
charge/discharge process.
: The charge will automatically adjust the
charge/discharge conditions
: Normal charge/discharge
: The preset current is maintained throughout the
charge/discharge process.
will cause
charging
Number of cells checking
After connecting the balance board, the charger can check
the number of cells. If the confirmed number of cells is not
correct, tap the ESC button to return to the previous page.
Re-check the parameters. With the correct number of cells,
the next page will be accessed automatically.
To initiate the process without a balance board, the cell can
be activated and the number of cells programmed into the
cell. Tapping the Enter button
will cause the charg-
er to immediately initiate
the charging process.
This page (left) shows the cycle process with the parameters and graph.
Both the voltage and current values will increase to the preset parameters.
The preset current may be limited by the charge/discharge capacity and
ithe nput voltage setup. The max charging process at 120W with a max
discharging process at 30W.
Cycle operating screen
The operating indicator blinks at the top
The number of operating cycles is shown
Tap the graph to display the operating data
Tap the part in the red circle (left) to display the set current
window. The charge/discharge current parameters used dur-
ing the operations can then be entered. Tap the
to close the set current window. These parameters are used
by the charger during the operation and are not stored in the
memory.
button
26