Large Freestanding Stove F3101L - Masport F2101 Owners & Installation Manual

Table of Contents

Advertisement

each Masport Large Freestanding Woodstove
(F3101L). It is located in the upper right corner
of the back of the stove. We have printed a copy
of the contents here for your review.
NOTE: Masport units are constantly being im-
TESTED TO:
F3100L
WITH
AIRMATE SHIELD
F3100L WITH AIRMATE SHIELD
MEASURE
FROM
RESIDENTIAL INSTALLATION USING
SINGLE WALL CONNECTOR
SIDEWALL
BACKWALL
CORNER
INSTALLATION USING LISTED DOUBLE WALL
CONNECTOR - MOBILE HOME
SIDEWALL
BACKWALL
CORNER
INSTALLATION USING LISTED DOUBLE WALL
CONNECTOR - RESIDENTIAL CLOSE CLEARANCE
SIDEWALL
BACKWALL
CORNER
INSTALLATION USING LISTED DOUBLE WALL
SIDEWALL
BACKWALL
MINIMUM CLEARANCE BETWEEN HORIZONTAL CHIMNEY CONNECTOR AND COMBUSTIBLE MATERIALS - 460 MM (18 IN.). CLEARANCE MAY BE
REDUCED BY THE USE OF LISTED PIPE SHIELDS, WALL PROTECTORS OR OTHER MEANS APPROVED BY LOCAL BUILDING OR FIRE OFFICIALS.
COMBUSTIBLE FLOOR MUST BE PROTECTED BY NON-COMBUSTIBLE MATERIAL EXTENDING BENEATH THE HEATER AND TO THE FRONT AND SIDES
AS INDICATED OR TO THE NEAREST PERMITTED COMBUSTIBLE MATERIAL.
FOR USE WITH SOLID WOOD FUEL ONLY. USE OF OTHER FUELS MAY DAMAGE HEATER AND CREATE A HAZARDOUS CONDITION. DO NOT OBSTRUCT
COMBUSTION AIR OPENINGS. OPERATE ONLY WITH FIREBRICKS IN PLACE. OPERATE ONLY WITH DOOR CLOSED - OPEN FEED DOOR TO FEED FIRE
ONLY. DO NOT USE GRATE OR ELEVATE FIRE. BUILD WOOD FIRE DIRECTLY ON HEARTH. DO NOT OVERFIRE - IF HEATER OR CHIMNEY CONNECTOR
GLOWS YOU ARE OVERFIRING. INSPECT AND CLEAN CHIMNEY AND CONNECTOR FREQUENTLY. UNDER CERTAIN CONDITIONS OF USE CREOSOTE
BUILDUP MAY OCCUR RAPIDLY. KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIAL AWAY FROM HEATER. REPLACE GLASS ONLY WITH
NEOCERAM GLASS.
OPTIONAL COMPONENT: FAN, ELECTRICAL RATING: VOLTS 115, 60 HZ, 2 AMPS
COMPONENTS REQUIRED FOR MOBILE HOME INSTALLATION: OUTSIDE AIR KIT AND ONE OF THE FOLLOWING DOUBLE WALL CONNECTOR
IN CANADA:
LISTED SECURITY MODEL DP, OR OLIVER MACLEOD PRO-VENT PV DOUBLE WALLED CONNECTOR WITH LISTED CHIMNEY SYSTEM:
SECURITY MODEL S2100, ICC EXCEL 2100.
IN USA:
VENT MODEL DVL, GSW SUPER PIPE 6, METAL-FAB DOUBLE WALL. CONNECTED TO ONE OF THE FOLLOWING COMPATIBLE CHIMNEY SYSTEMS
SECURITY MODEL S2100 OR MODEL ASHT, SELKIRK MODEL SSII, OLIVER MACLEOD PRO JET 3103, SIMPSON DURA PLUS, GSW MODEL SC OR METAL-
FAB TEMP/GUARD, AMERI-TEC HS, ICC EXCEL 2100 . USE CHIMNEY COMPONENTS AS SPECIFIED IN INSTALLATION INSTRUCTIONS.
UNITED STATES
Masport Freestanding Woodstove
proved. Check the label on the unit and if there
is a difference, the label on the unit is the
correct one.
LISTED SPACE HEATER, SOLID FUEL TYPE,
MOBILE HOME INSTALLATION
MODEL:
REGENCY LARGE FREESTANDING STOVE - F3100L
CSA B366.2 / ULC S627 / UL 1482
INSTALL AND USE ONLY IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION AND OPERAT-
ING INSTRUCTIONS.
INSTALLATION INSPECTION IN YOUR AREA. USE 150 MM (6 IN.) DIAMETER MINIMUM 24 MSG BLACK OR
26 MSG BLUED STEEL CONNECTOR WITH LISTED FACTORY-BUILT CHIMNEY SUITABLE FOR USE WITH
SOLID FUELS OR MASONRY CHIMNEY.
SEE LOCAL BUILDING CODE AND MANUFACTURER'S INSTRUCTIONS FOR PRECAUTIONS REQUIRED
FOR PASSING A CHIMNEY THROUGH A COMBUSTIBLE WALL OR CEILING.
F3100L WITHOUT
CONNECTOR THROUGH COMBUSTIBLE WALL OR CEILING. DO NOT CONNECT THIS UNIT TO A CHIMNEY
AIRMATE SHIELD
FLUE SERVING ANOTHER APPLIANCE.
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
FLUE
HEATER
CENTER-LINE
A 460
mm / 18 in
D 810
mm / 32
in
B 305
mm / 12 in
E 470
mm / 18.5 in
C 215
mm / 8.5in
F
560
mm / 22
in
A 460
mm / 18 in
D 810
mm / 32
in
B 240
mm / 9.5in
E 405
mm / 16
in
C 255
mm / 10 in
F
595
mm / 23.5 in
A 405
mm / 16 in
D 760
mm / 30
in
B 240
mm / 9.5in
E 405
mm / 16
in
C 215
mm / 8.5in
F
560
mm / 22
in
CONNECTOR - ALCOVE
G 405
mm / 16 in
I
760
mm / 30
in
H 240
mm / 9.5in
J
405
mm / 16
in
LISTED DOUBLE WALL CONNECTORS SECURITY MODEL DP, SELKIRK MODEL DS, OLIVER MACLEOD PRO VENT PV, SIMPSON DURA
ENVIRONMENTAL
PROTECTION
AGENCY
HOT WHILE IN OPERATION DO NOT TOUCH.
CLOTHING AND FURNITURE AWAY . CONTACT MAY CAUSE
SKIN BURNS. READ NAMEPLATE AND INSTRUCTIONS.
SUITABLE FOR
REPORT NO.6623 (MAY 93)
CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND
F3100L
WITHOUT AIRMATE SHIELD
MEASURE
FLUE
FROM
HEATER
CENTER-LINE
RESIDENTIAL INSTALLATION USING
SINGLE WALL CONNECTOR
SIDEWALL
A 510
mm / 20
in
D 860
BACKWALL
B 355
mm / 14
in
E 520
CORNER
C 265
mm / 10.5 in
F
610
INSTALLATION USING LISTED DOUBLE WALL
CONNECTOR - MOBILE HOME
SIDEWALL
A 510
mm / 20 in
D 860
BACKWALL
B 305
mm / 12 in
E 470
CORNER
C 255
mm / 10 in
F
595
INSTALLATION USING LISTED DOUBLE WALL
CONNECTOR - RESIDENTIAL CLOSE CLEARANCE
SIDEWALL
A 510
mm / 20 in
D 860
BACKWALL
B 305
mm / 12 in
E 470
CORNER
C 215
mm / 8.5in
F
560
ALCOVE INSTALLATION
REQUIRES AIRMATE SHIELD
MANUFACTURED BY:
FIREPLACE PRODUCTS INTERNATIONAL LTD.
6988 VENTURE ST.
DELTA, BC
CERTIFIED TO COMPLY WITH
PARTICULATE EMISSION STANDARDS.
CAUTION
SAFETY LABEL
102
DO NOT REMOVE THIS LABEL
102
DO NOT PASS CHIMNEY
BACKWALL
B
E
A
D
BACKWALL
mm / 34
in
H
J
mm / 20.5 in
mm / 24
in
G
G
I
mm / 34
in
mm / 18.5 in
ADJACENT WALL
mm / 23.5 in
C
mm / 34
in
F
mm / 18.5 in
mm / 22
in
BACK
FLOOR
PROTECTION
K
405 mm / 16 in
L
150 mm / 6 in
M
150 mm / 6 in
V4G 1H4
MADE IN CANADA
JULY 1990,
KEEP CHILDREN,
M
L
K
FRONT
WD
908-351
09/00
5