YASKAWA VS mini J7 Series Instruction Manual page 103

Vs mini j7 series compact general-purpose inverter
Hide thumbs Also See for VS mini J7 Series:
Table of Contents

Advertisement

Voltage Class
Model
phase
CIMR-J7 * C????
Status Indicator
LED
Digital Operator
Terminals
Wiring Distance
between Inverter
and Motor
Enclosure
Cooling Method
Ambient Temperature
Humidity
Storage Temperature*
Location
Elevation
Vibration
*
Temperature during shipping (for short period)
† If the wiring distance between inverter and motor is long, reduce the inverter carrier
frequency.
For details, refer to "Reducing motor noise or leakage current (n46)" on page 57.
3-
40P2
40P4
RUN and ALARM provided as standard LED's
Available to monitor frequency reference,
output frequency, output current
Main circuit: screw terminals
Control circuit: plug-in screw terminal
100m (328ft) or less †
Open chassis
Cooling fan is provided for the following models:
400V, 1.5kW (3HP) or large inverters (3-phase)
Other models are self cooling
Open chassis: -10 to +50°C (14 to 122°F)
95%RH or less (non-condensing)
-20 to +60°C (-4 to 140°F)
Indoor (free from corrosive gases or dust)
1000m (3280ft) or less
Up to 9.8m / S
(1G) at less than 20Hz,
2
up to 2m / S
(0.2G) at 20 to 50Hz
2
400V 3-phase
40P7
41P5
42P2
(not frozen)
43P0
44P0
103