Resetting The Camera To Factory Defaults; Activating Event Control For Web Applications; Deactivating Text And Logo Options; Deactivating The Automatic Daily Reboot Of The Camera - Mobotix M22M Operator's Manual

Hide thumbs Also See for M22M:
Table of Contents

Advertisement

M22M Camera Manual Part 1

1.6.5 Resetting the Camera to Factory Defaults

All settings of the MOBOTIX camera can be reset to the factory default settings. This
makes sense if you have, for example, obtained a camera without any information
or you would like to reset all settings after testing the camera. In order to perform
this procedure, you need to have access to the administration area of the camera
(admins group). Open Admin Menu > Reset ... to reset the camera to factory de-
faults.
Note:
All defined users will be deleted and the admin password will be reset to
the factory default
when you reset the camera using Admin Menu > Reset ...
Proceed according to section 3.6, Starting the Camera Using the Factory IP
Address , if you would like to maintain existing users.
1.6.6 Activating Event Control for Security Applications
In its default configuration, the camera's event control and video motion detection
features are
not
enabled. In order to activate event control as a whole, open
Setup Menu > General Event Settings and activate the Arming switch or click on
the Arm & Record softbutton of the browser interface. The video motion detection
window is visible again (dotted frame in the center of the live image) and the cam-
era stores images as soon as the video motion window detects movements.

1.6.7 Deactivating Text and Logo Options

As the camera arming has been deactivated in its default configuration (see prece
ding section), the MOBOTIX camera only displays the Text WWW.MOBOTIX.COM,
the time stamp and the MOBOTIX logo at the top of the image. Once the camera
arming has been activated (see section 1.6.6), the text at the bottom of the live
image (event, action and messaging symbols) will also appear.
You can deactivate the status text at the bottom and the text at the top left corner of
the live image by setting Text Display in the Setup Menu > Text & Display Settings
dialog to Off . Setting Text Display to Date & Time will only display the time stamp in
the live image.
In order to hide the logo in the live image, open Admin Menu > Logo Profiles and
set Logo Display to Disable .

1.6.8 Deactivating the Automatic Daily Reboot of the Camera

In its default configuration, the MOBOTIX camera automatically reboots every
morning at 3:36 am. The reason for this is that external influences (e.g. radiation in
high locations) can lead to camera malfunctions. The automatic reboot will refresh
the camera's memory and will ensure proper operation without requiring any inter-
action on the part of the user.
Open Admin Menu > Time Tasks and deactivate or delete the Reboot camera
task. This will prevent the camera from rebooting automatically.
© MOBOTIX AG • Security-Vision-Systems • Made in Germany
www.mobotix.com • sales@mobotix.com
19
/76
The configuration can also
be reset partially
If the dotted rectangle in
the live image is visible,
the camera is armed
Text and logos can be also
deactivated or customized
to your liking