accordance with their instructions. In some cases it may be necessary to fit an adaptor to
increase the diameter of the flue to the minimum required 150 mm section of the chimney
or liner.
Commissioning and handover
Ensure all parts are fitted in accordance with the instructions.
On completion of the installation allow a suitable period of time for any fire cement and
mortar to dry out, before lighting the stove. Once the stove is under fire check all seals for
soundness and check that the flue is functioning correctly and that all products of
combustion are vented safely to atmosphere via the chimney terminal.
On completion of the installation and commissioning ensure that the operating instructions
for the stove are left with the customer. Ensure to advise the customer on the correct use
of the appliance and warn them to use only the recommended fuel for the stove.
Advise the user what to do should smoke or fumes be emitted from the stove. The
customer should be warned to use a fireguard to BS 8423:2002 (Replaces BS 6539) in the
presence of children, aged and/or infirm persons.
READ THE INSTRUCTION BOOK AND THESE INSTRUCTIONS CAREFULLY
BEFORE USING THE STOVE
WARNING NOTE
Properly installed, operated and maintained this stove will not emit fumes into the dwelling. Occasional fumes
from de-ashing and re-fuelling may occur. However, persistent fume emission is potentially dangerous and
must not be tolerated. If fume emission does persist, then the following immediate action should be taken:-
(a) Open doors and windows to ventilate the room and then leave the premises.
(b) Let the fire go out.
(c) Check for flue or chimney blockage and clean if required
(d) Do not attempt to relight the fire until the cause of the fume emission has
been identified and corrected. If necessary seek expert advice.
The most common cause of fume emission is flueway or chimney blockage. For your own
safety these must be kept clean at all times.
IMPORTANT NOTES
General
Before lighting the stove check with the installer that the installation work and
commissioning checks described above have been carried out correctly and that the
chimney has been swept clean, is sound and free from any obstructions. As part of the
stoves' commissioning and handover the installer should have shown you how to operate
the stove correctly.