Top cover
Lamp
To insert the lamp MSD 250W/2 open the top cover of the projector-head (see the drawing to identify which cover
is top) by loosening the 3 screws on the cover.
Then open the small lamp cover by loosening 2 fastening screws (see the drawing).
If changing the lamp, remove the old lamp from the socket.
Insert the lamp to the socket.
Do not install a lamp with a higher wattage! A lamp like this generates temperatures the device is not designed
for.
Damages caused by non-observance are not subject to warranty. Please follow the lamp manufacturer's notes!
Do not touch the glass bulb with bare hands during the installation! Make sure that the lamp is installed tightly into
the lampholder system.
Adjust the optimal distance 1-1.5 mm from the lens by turning the screw "A" (see the drawings "Lamp adjustment"
below) on the rear panel of the head.
Then close the small lamp cover by tighten 2 fastening screws again.
Reclose the top cover of the head and tighten the 3 screws.
Before striking the lamp, reset the "LAti/rSEt" and "LASt/rSEt"counters in the "InFO" menu by pressing the
"Up" and "Down" buttons in one time and then confirming with the "Enter"-button.
Do not operate this fixture with opened housing-cover!

Lamp adjustment

Correct
optimum distance
1-1,5 mm
Fastening screws
rear panel of the moving head
Screw"B"
Screw"A"
Fastening screws
Keep optimum distance to the lens
8
Lamp cover
Incorrect