4.2 Installing the lamp

To insert the new lamp.
1. Disconnect the fixture from power and allow it to cool at least 20 minutes.
2. Make sure that the fixture´s head is in the position as
shown on the picture (notices on the lamp cover are in
a readable position) .Loosen the three quarter-turn
fasteners (1) on the lamp cover to
open this cover.
3. Holding the lamp by its ceramic base, carefully
turn the lamp to the left to loosen the lamp from
the lamp holder.
Gently pull the lamp out of the lamp holder
4. Holding the new lamp by its ceramics base and keeping its orientation
as shown at the picture below,
gently insert the lamp to the lamp holder and turn its base
into slots in the lamp holder.
Do not install a lamp with a higher wattage! A lamp like this generates temperatures the device is not de-
signed for. Damages caused by non-observance are not subject to warranty.
Please follow the lamp manufacturer's notes! Do not touch the glass bulb bare hand during the
installation!
5. Re-insert the lamp cover and tighten the three quarter-turn fasteners (1).
6. Switch on the fixture.
7. Align the lamp (see instructions below)
8. Reset the "Lamp On Time" and "Lamp Strikes" counters in the menu "Information".

4.3 Lamp adjustment

The lamp holder is aligned at the factory. Due to differences between lamps,the fine adjustment may improve
light performance:
To adjust the lamp in the fixture.
1. Switch on the fixture and after its reset turn on the
lamp.
2. Go to the "Service" menu and select the item "Adjust
Lamp" to project the light beam on the wall.
3. Use items in this menu to focus the light beam
4. Turn adjustment screws (2) one after another until you
center the hot spot (the brightest part of the beam) and
reach a max. light intensity at desired light distribution.
DANGER ! Unplug from mains before lamp installing !
Make sure that the lamp is installed tightly into the lamp socket.
Do not operate this fixture with open lamp cover!
to the right until two lamp electrodes snap