4. Installation

4.1 Fitting the lamp

DANGER !
Install the lamps with the device switched off only.
Unplug from mains before !
To insert the lamp PHILIPS MSR 575/2 95 V/575 W GX-9,5 open the small cover at the head's rear panel (see the
drawing) by loosening the 3 Phillips screws X, Y and Z on the cover.
Gently pull out the lamp assembly.
If changing the lamp, remove the old lamp from the socket. Insert the lamp to the socket.
Do not install a lamp with a higher wattage! A lamp like this generates temperatures the device is not designed for.
Damages caused by non-observance are not subject to warranty. Please follow the lamp manufacturer's notes!
Do not touch the glass-bulb bare-handed during the installation! Make sure that the lamp is installed tightly into
the lampholder system.
Reinsert the lamp assembly and tighten the 3 screws again.
Before striking the lamp, reset the "LAti" counter in the main menu of the Control Board, by pressing the "Up"
and "Down" buttons in one time and then confirming with the Enter-button.
Lamp assembly:
Lamp cover
3 phillips screws "X,Y,Z"
Do not operate this fixture with opened housing-cover!

4.2 Lamp adjustment

The WASH 575 XT lampholder is aligned at the factory. Due to differences between lamps, fine adjustment may
improve light performance.
Strike the lamp, open the shutter and the iris, set the dimmer intensity onto 100 % and focus the light on a flat
surface (wall). Center the hot-spot (the brightest part of the beam) using the 3 adjustment screws "A, B, C". Turn
one screw at a time to drag the hot-spot diagonally across the projected image. If you cannot detect a hot-spot,