#@TRIGOFF<CR>
Purpose
Disable the software trigger
Remarks
"0x23" + "0x40" + "0x54" + "0x52" + "0x49" + "0x47" + "0x4f" + "0x46" + "0x46"
+ "0x0d"
#@TRIGON<CR>
Purpose
Enable the software trigger
Remarks
"0x23" + "0x40" + "0x54" + "0x52" + "0x49" + "0x47" + "0x4f" + "0x4e" + "0x0d"

EXAMPLE

You may run HyperTerminal.exe on the host computer to send serial commands to the
scanner via BT SPP or USB Virtual COM.
For the scanner to stop immediately –
D
For the scanner to resume working –
E
For the scanner to change the beeper to medium volume and beep –
#@101011<CR>
#@////<CR>
For the scanner to change the beeper to minimal volume and beep –
#@101010<CR>
#@////<CR>
For the scanner to change the beeper frequency to 8 kHz (for Good Read Beep only)
and beep –
#@101001<CR>
#@////<CR>
For the scanner to change the beeper length to longest (for Good Read Beep only)
and beep –
#@101008<CR>
#@////<CR>
For the scanner to save the settings, send the serial command "#@109999" –
#@101011<CR>
#@109999<CR>
Note: (1) For USB Virtual COM, you can only configure the first scanner that connects to
3610. To identify the scanner, you may send the serial command to have it
respond with a beep.
(2) For BT SPP, you can configure up to seven scanners at the same time.