Multiple Zipp LEDs (DMX Control)

1. Fasten the effect light onto firm trussing
2.
Always use a safety cable (ordercode 70140 / 70141).
3. Use a 3-p XLR cable to connect the Zipp LEDs and other devices.
4. Link the units as shown in (figure 5), Connect a DMX signal cable from the first unit's DMX "out" socket to
the second unit's "in" socket. Repeat this process to link the second, third, and fourth units.
5. Supply electric power: Plug electric mains power cords into each unit's IEC socket, then plug the
other end of the mains power cord into proper electric power supply sockets, starting with the first unit.
Do not supply power before the whole system is set up and connected properly.
Note : Link all cables and set dip switches before connecting electric power
Note: After switching on, the Zipp LED will automatically detect whether DMX 512 data is received or not.
If there is
no data received at the DMX-input, the "LED " on the control panel will not flash.
The problem may be:
- The XLR cable from the controller is not connected with the input of the Zipp LED.
- The controller is switched off or defective, the cable or connector is detective, or the signal wires are
swapped in the input connector.
Note: It's necessary to insert a XLR termination plug (with 120 Ohm) in the last fixture in order to ensure
proper transmission on the DMX data link.