Sym MAXSYM 400i Service Manual page 126

Hide thumbs Also See for MAXSYM 400i:
Table of Contents

Advertisement

Measure the outer diameter of piston pin.
Service Limit: 16.96 mm
Measure the inner diameter of connecting rod
small end.
Service Limit: 17.064 mm
Measure the inner diameter of piston pin hole.
Service Limit: 17.02 mm
Calculate clearance between piston pin and its
hole.
Service Limit: 0.02 mm
Measure the piston outer diameter.
Caution
The measurement position is 10 mm distance
from piston bottom side, and 90° to piston pin.
Service limit: : : :
LM25W5: 70.380 mm
LM30W: 72.380 mm
Compare measured value with service limit to
calculate the clearance between piston and
cylinder.
To this chapter contents
7. Cylinder / Piston
7-5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents