17. Electrical System
Inspection on ignition coil
Remove the right floor garnish.
Disengage the connector of the ignition coil.
Measure the resistance between the terminals of
the primary winding.
Standard resistance: 2.8 ±15% (20ºC)
Replacement of ignition coil
Remove the cap from the spark plug.
Loosen 2 bolts and replace the ignition coil if
necessary.
Inspection of crank position sensor
Remove luggage box (bolt×6).
Disconnect the coupler of the crank position
sensor and measure the resistance between the
terminals of green/white and blue/yellow.
Standard resistance: 80~160
Caution
It is not necessary to remove the coil from the
engine during this process.
Please refer to the section 11 for disassembly of
coil.
17-10
To this chapter contents
Ignition coil
Coupler
Spark plug cap