AISV
To this chapter contents
Functional Description:
Control power, has two-pin socket, one for the power supply pin, one
for grounding pin.
Secondary air injection solenoid valve at the Idle (3500 rpm below)
actuator.
At Idling, ECU control solenoid valve by the grounding circuit to be
moving or closing.
Testing Procedures:
Resistance Confirmation:
Use of the "meter" Ohm stalls ( ), measurement of the secondary air
injection solenoid valve resistance value.
Detection judge:
Resistance value =
26 ± 2.6 (20 )
Treatment of abnormal phenomena:
Secondary air injection solenoid valve internal short circuit or open
circuit, or coupler bad contact.
Check whether the abnormal wire harness lines.
Secondary air injection solenoid valve anomaly, the proposed
replacement of the new one.