Sony HVR-Z7J Service Manual page 322

Digital hd video camera recorder
Hide thumbs Also See for HVR-Z7J:
Table of Contents

Advertisement

2. COMPONENT OUT Y Level Adjustment
(TT-007 board)
Mode
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified value
Switch setting:
1) REC FORMAT (Menu setting) ............................. HDV1080i
Adjusting method:
Order Page Address Data
1
0
01
2
3
71
3
0
10
8
4
5C
(18)
8
5
5D
(18)
6
0
10
7
C
8C
8
C
8C
9
10
0
10
8
11
5C
(18)
8
12
5D
(18)
13
0
10
14
3
70
15
3
70
16
0
01
Note: For the bit values, refer to "6-4. SERVICE MODE", "4-4.
3. Bit value discrimination".
B
C
HVR-Z7J/Z7U/Z7N/Z7E/Z7P/Z7C
CAMERA mode
Arbitrary
Y signal terminal of COMPONENT
OUT jack (75 Ω terminated)
Oscilloscope
C
8C
Y level: A = 1000 ± 10 mVp-p
Sync level: B = C = 300 ± 10 mVp-p
Procedure
01
01
Press PAUSE (Write) button.
01
Set the bit value of bit0 is
"1", and press PAUSE
(Write) button. (Note)
05
Press PAUSE (Write) button.
00
Change the data and set the
Y signal level (A) to the
specified value.
Press PAUSE (Write) button.
Check the sync signal (B, C)
to the specified value.
01
Set the bit value of bit0 is
"0", and press PAUSE
(Write) button. (Note)
00
Press PAUSE (Write) button.
00
10
Press PAUSE (Write) button.
Check the data changes to
"11".
00
H
Fig. 6-3-6
3. COMPONENT OUT Pr Level Adjustment
(TT-007 board)
Mode
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified value
Switch setting:
1) REC FORMAT (Menu setting) ............................. HDV1080i
Adjusting method:
Order Page Address Data
1
0
2
3
3
0
8
4
(18)
8
5
(18)
6
0
7
C
8
C
9
10
0
8
11
(18)
8
12
(18)
13
0
14
3
15
3
16
0
Note: For the bit values, refer to "6-4. SERVICE MODE", " 4 - 4 .
3. Bit value discrimination".
B
C
A
6-132
CAMERA mode
Arbitrary
Pr signal terminal of COMPONENT
OUT jack (75 Ω terminated)
Oscilloscope
C
8E
Pr level: A = 525 ± 10 mVp-p
Sync level: B = C = 300 ± 10 mVp-p
Procedure
01
01
71
01
Press PAUSE (Write) button.
10
01
Set the bit value of bit0 is
5C
"1", and press PAUSE
(Write) button. (Note)
5D
05
Press PAUSE (Write) button.
10
00
Change the data and set the
Pr signal level (A) to the
8E
specified value.
8E
Press PAUSE (Write) button.
Check the sync signal (B, C)
to the specified value.
10
01
Set the bit value of bit0 is
"0", and press PAUSE
5C
(Write) button. (Note)
5D
00
Press PAUSE (Write) button.
10
00
70
10
Press PAUSE (Write) button.
Check the data changes to
70
"11".
01
00
H
Fig. 6-3-7
A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hvr-z7uHvr-z7nHvr-z7pHvr-z7cHvr-z7e

Table of Contents