Sony HVR-Z7J Service Manual page 242

Digital hd video camera recorder
Hide thumbs Also See for HVR-Z7J:
Table of Contents

Advertisement

25. Auto White Balance Check (ND4)
Subject
Filter
Measurement Point
Measuring Instrument
Specified Value
Note 1: Perform "Auto White Balance Standard Data Input
(ND4)", "LV Standard Data Input" and "Auto White Bal-
ance Adjustment (ND4)" before this adjustment.
Note 2: Check that the data of page: 6, address: 02 is "00".
If not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Switch setting
1) POWER ......................................................... CAMERA mode
2) ND FILTER ............................................................................ 4
3) D. EXTENDER (Menu setting) ...................................... OFF
4) STEADY SHOT (Menu setting) ..................................... OFF
5) REC FORMAT (Menu setting) ............................. HDV1080i
Checking method:
Order Page Address Data
1
0
01
2
6
9B
3
6
99
4
6
07
5
0
10
6
6
07
(16)
6
7
40
(16)
8
0
10
9
6
41
10
6
CA
11
6
C9
OUTDOOR white balance check
12
6
01
13
6
02
14
6
0C
15
6
01
HVR-Z7J/Z7U/Z7N/Z7E/Z7P/Z7C
RadarW
RadarW
RadarW
RadarW
RadarW
Clear chart (Color reproduction
adjustment frame)
ND filter 1.0, 0.4 and 0.1
Adjusting remote commander
Data of page: 6, address: 0C is "00"
Procedure
01
Check the bit value of bit2 is
"0". (Note 3)
Check the data is "03".
Check the data is "04".
01
Check the data is "04".
01
00
01
85
10
4F
Press PAUSE (Write) button.
Check the data changes to
"01".
Check the data is "00".
00
Press PAUSE (Write) button.
Order Page Address Data
INDOOR white balance check
16
6
01
17
6
02
18
6
0C
19
6
01
InOut check
20
21
6
C9
22
6
13
23
24
6
01
25
6
02
26
6
0C
27
6
01
28
Note 3: For the bit values, refer to "6-4. SERVICE MODE", "4-
4. 3. Bit value discrimination".
Processing after Completing Adjustment:
Order Page Address Data
1
6
C9
2
6
CA
3
0
10
6
4
40
(16)
5
0
10
6
6
41
7
6
13
8
0
01
6-58
Procedure
0F
Press PAUSE (Write) button.
Check the data changes to
"01".
Check the data is "00".
00
Press PAUSE (Write) button.
Place the ND filter 1.5 (1.0
+0.4 + 0.1) on the lens.
11
BE
Wait for 3 seconds.
4B
Press PAUSE (Write) button.
Check the data changes to
"01".
Check the data is "00".
00
Press PAUSE (Write) button.
Remove the ND filter 1.5
(1.0 + 0.4 + 0.1) on the lens.
Procedure
00
00
01
00
00
00
00
00

Hide quick links: