Ver. 1.5 2009.02
5-1. Optical Path Differencial Adjustment (ND1 (CLR))
RadarW
RadarW
RadarW
RadarW
RadarW
(Using the minipattern box or flange back adjust-
ment jig)
Perform the flange back adjustment on the body side. In which-
ever case, the focus will be deviated during auto focusing/manual
focusing.
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified value
Note 1: Dark Siemens star chart.
Note 2: Perform the adjustment with the lens in horizontal state.
Note 3: If reading/writing data on pages 6F, set data: 06 to page:
0, address: 10, and then select pages F. By this data set-
ting, the pages 6F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to "00".
Note 4: Check that the data of page: 6, address: 02 is "00". If
not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Note 5: Don't touch the zoom lever during adjustment.
Note 6: After adjustment, if the focusing to a subject located at
infinity failed, increase the illuminance of the chart and
perform readjustment.
Note 7: Check that the ZOOM switch is in SERVO position.
Note 8: When mounting the lens, mount the lens firmly, free from
a play and tighten up the lever.
Switch setting
1) POWER ......................................................... CAMERA mode
2) ND FILTER ............................................................................ 1
3) REC FORMAT (Menu setting) ............................. HDV1080i
4) ZOOM switch (Lens block) ....................................... SERVO
HVR-Z7J/Z7U/Z7N/Z7E/Z7P/Z7C
Siemens star chart with ND filter for
minipattern box (Note 1) or flange
back adjustment jig
Adjusting remote commander
6F
20, 21, 28
Data of pege: 16, address: 0C is "00"
Adjusting method:
Order Page Address Data
1
0
01
2
0
10
F
3
26
(9F)
4
0
10
5
6
07
6
0
10
6
7
07
(16)
8
0
10
9
6
61
10
11
6
99
12
0
10
6
13
02
(16)
14
0
10
15
6
02
16
0
10
6
17
2C
(16)
18
0
10
19
6
4D
20
6
64
21
6
01
22
0
10
6
23
01
(16)
24
25
0
10
26
6
01
27
0
10
6
28
01
(16)
29
0
10
30
6
02
31
0
10
6
32
0C
(16)
Note 9: For the bit values, refer to "6-4. SERVICE MODE",
"4-4. 3. Bit value discrimination".
Note 10: The adjustment data will be automatically input to page:
6F, address: 20, 21, 28.
6-29
Procedure
01
09
Set the bit value of bit0 is "1",
and press PAUSE (Write)
button. (Note 9)
00
Check the data is "04".
01
Check the data is "04".
00
01
Wait for 3 seconds.
Check the data is "00".
01
Check the data is "00".
00
Check the data is "00".
01
01
00
40
04
13
Press PAUSE (Write) button.
01
13
Press PAUSE (Write) button.
Wait for 1 seconds.
00
Press PAUSE (Write) button.
51
(Note 10)
01
Press PAUSE (Write) button.
51
(Note 10)
00
Check the data changes to
"01".
01
Check the data is "00".

Hide quick links: