6-2. Flange Back Check (ND2)
(Using the flange back adjustment jig)
Subject
Measurement Point
Measuring Instrument
Specified value
Note 1: Check that the data of page: 0, address: 10 is "00".
Note 2: Check with the monitor larger than 40 inches.
Switch setting
1) POWER ......................................................... CAMERA mode
2) ND FILTER ............................................................................ 2
3) REC FORMAT (Menu setting) ............................. HDV1080i
Checking method:
Order Page Address Data
1
2
0
01
3
6
99
4
0
10
6
5
40
(16)
6
0
10
7
6
41
8
6
4D
9
6
61
10
11
6
01
12
0
10
6
13
01
(16)
14
6
15
2C
(16)
16
Processing after Completing Adjustment:
Order Page Address Data
6
1
01
(16)
6
2
2C
(16)
6
3
40
(16)
4
0
10
5
6
01
6
6
61
7
6
41
8
6
4D
9
0
01
HVR-Z7J/Z7U/Z7N/Z7E/Z7P/Z7C
Flange back adjustment jig
(Siemens star chart)
(Illuminance: 250 ± 50 lux)
Check operation on monitor TV
(Note 2)
Focused at the TELE end and WIDE
end
Procedure
Set the ND FILTER to "2".
01
Check the data is "01".
01
01
00
01
40
01
Wait for 3 seconds.
13
Press PAUSE (Write) button.
01
13
Press PAUSE (Write) button.
Wait for 1 second.
02
Check that the lens is
focused while zooming from
TELE end to WIDE end.
Procedure
00
Press PAUSE (Write) button.
00
00
00
00
Press PAUSE (Write) button.
00
00
00
00
6-3. Flange Back Check (ND3)
(Using the flange back adjustment jig)
Subject
Measurement Point
Measuring Instrument
Specified value
Note 1: Check that the data of page: 0, address: 10 is "00".
Note 2: Check with the monitor larger than 40 inches.
Switch setting
1) POWER ......................................................... CAMERA mode
2) ND FILTER ............................................................................ 3
3) REC FORMAT (Menu setting) ............................. HDV1080i
Checking method:
Order Page Address Data
1
2
0
01
3
6
99
4
0
10
6
5
40
(16)
6
0
10
7
6
41
8
6
4D
9
6
61
10
6
1C
11
6
1D
12
6
1E
13
14
6
01
15
0
10
6
16
01
(16)
17
6
18
2C
(16)
19
6-38
Flange back adjustment jig
(Siemens star chart)
(Illuminance: 250 ± 50 lux)
Check operation on monitor TV
(Note 2)
Focused at the TELE end and WIDE
end
Procedure
Set the ND FILTER to "3".
01
Check the data is "02".
01
01
00
01
40
01
33
0F
00
Wait for 3 seconds.
13
Press PAUSE (Write) button.
01
13
Press PAUSE (Write) button.
Wait for 1 second.
02
Check that the lens is
focused while zooming from
TELE end to WIDE end.