Tension Control Monitor Output (Pr. 52) - Mitsubishi Electric FR-A700-A1 Instruction Manual

Dancer control function/tension control function
Table of Contents

Advertisement

Details of the tension control
4.6.6

Tension control monitor output (Pr. 52)

The internally converted values during tension control can be output as monitored items to the PU/DU display.
Set a value corresponding to the desired monitored item in Pr. 52.
The selected monitored item is displayed on PU/DU instead of the voltage monitor.
When the tension control is disabled, 0% is displayed.
Minimum
Signal Name
Increment
Tension
0.1%
command
Mechanical
loss
0.1%
compensation
Inertia
0.1%
compensation
The value displayed on the monitor is a signal value plus 500%.
Signal Value
Monitor Display
-400% to -0.1%
100 to 499.9%
0%
500.0%
0.1% to 400%
500.1 to 900%
66
Modbus-RTU
Pr.52 Setting
Register
63
40263
64
40264
65
40265
Mitsubishi Inverter
Protocol
Monitoring
Number
3F
40
41