Parameter
Name
144
Speed setting switchover
145
PU display language selection
148
Stall prevention level at 0V input
149
Stall prevention level at 10V input
150
Output current detection level
Output current detection signal delay
151
time
152
Zero current detection level
153
Zero current detection time
Voltage reduction selection during stall
154
prevention operation
RT signal function validity condition
155
selection
156
Stall prevention operation selection
157
OL signal output timer
158
AM terminal function selection
160
User group read selection
Frequency setting/key lock operation
161
selection
Automatic restart after instantaneous
162
power failure selection
Stall prevention operation level for
165
restart
Output current detection signal
166
retention time
Output current detection operation
167
selection
168
Parameter for manufacturer setting. Do not set.
169
170
Watt-hour meter clear
171
Operation hour meter clear
User group registered display/batch
172
clear
173
User group registration
174
User group clear
178
STF terminal function selection
179
STR terminal function selection
180
RL terminal function selection
181
RM terminal function selection
182
RH terminal function selection
183
RT terminal function selection
184
AU terminal function selection
Setting Range
0, 2, 4, 6, 8, 10, 102, 104,
106, 108, 110
0 to 7
0 to 220%
0 to 220%
0 to 220%
0 to 10s
0 to 220%
0 to 1s
0, 1
0, 10
0 to 31, 100, 101
0 to 25s, 9999
1 to 3, 5 to 14, 17, 18, 21,
24, 32 to 34, 39 to 44, 46
0, 1, 9999
0, 1, 10, 11
0, 1, 2, 10, 11, 12
0 to 220%
0 to 10s, 9999
0, 1
0, 10, 9999
0, 9999
9999, (0 to 16)
0 to 999, 9999
0 to 999, 9999
0 to 14, 16 to 18, 20,
22 to 28, 30, 32 to 35,
42 to 44, 51 to 60, 62,
64 to 67, 70, 71, 83 to 93,
9999
0 to 14, 16 to 18, 20,
23 to 28, 30, 32 to 35,
42 to 44, 51 to 59, 61, 62,
64 to 67, 70, 71, 83 to 93,
9999
0 to 14, 16 to 18, 20,
23 to 28, 30, 32 to 35,
42 to 44, 51 to 59, 62,
64 to 67, 70, 71, 83 to 93,
9999
0 to 14, 16 to 18, 20,
23 to 28, 30, 32 to 35,
42 to 44, 51 to 59, 62 to 67,
70, 71, 74, 83 to 93, 9999
PARAMETER LIST
Minimum
Initial
Setting
Value
Increments
1
4
1
0
0.1%
150%
0.1%
200%
0.1%
150%
0.1s
0s
0.1%
5%
0.01s
0.5s
1
1
1
0
1
0
0.1s
0s
1
1
1
0
1
0
1
0
0.1%
150%
0.1s
0.1s
1
0
1
9999
1
9999
1
0
1
9999
1
9999
1
60
1
61
1
0
1
1
1
2
1
3
1
4
Refer
Customer
to
Setting
Page
49
2
16
16
16
16
16
16
16
5

Advertisement

Table of Contents
loading

Table of Contents