PARAMETER LIST
Parameter
850
Brake operation selection
853
Speed deviation time
*6
854
Excitation ratio
858
Terminal 4 function assignment
859
Torque current
860
Second motor torque current
862
Notch filter time constant
863
Notch filter depth
864
Torque detection
865
Low speed detection
866
Torque monitoring reference
867
AM output filter
868
Terminal 1 function assignment
872
Input phase loss protection selection
873
Speed limit
*6
874
OLT level setting
875
Fault definition
Speed feed forward control/model
877
adaptive speed control selection
878
Speed feed forward filter
879
Speed feed forward torque limit
880
Load inertia ratio
881
Speed feed forward gain
Regeneration avoidance operation
882
selection
Regeneration avoidance operation
883
level
Regeneration avoidance at
884
deceleration detection sensitivity
Regeneration avoidance compensation
885
frequency limit value
886
Regeneration avoidance voltage gain
888
Free parameter 1
889
Free parameter 2
C0
FM terminal calibration
(900)
*7
C1
AM terminal calibration
(901)
*7
C2
Terminal 2 frequency setting bias
(902)
frequency
*7
C3
Terminal 2 frequency setting bias
(902)
*7
125
Terminal 2 frequency setting gain
(903)
frequency
*7
C4
Terminal 2 frequency setting gain
(903)
*7
C5
Terminal 4 frequency setting bias
(904)
frequency
*7
C6
Terminal 4 frequency setting bias
(904)
*7
126
Terminal 4 frequency setting gain
(905)
frequency
*7
C7
Terminal 4 frequency setting gain
(905)
*7
C12
Terminal 1 bias frequency (speed)
(917)
*7
12
Name
0, 1
0 to 100s
0 to 100%
0, 1, 4, 9999
0 to 500A, 9999/
0 to 3600A, 9999
0 to 500A, 9999/
0 to 3600A, 9999
0 to 60
0 to 3
0 to 400%
0 to 400Hz
0 to 400%
0 to 5s
0 to 6, 9999
0, 1
0 to 120Hz
0 to 200%
0, 1
0, 1, 2
0 to 1s
0 to 400%
0 to 200times
0 to 1000%
0 to 3
300 to 800V
0 to 5
0 to 10Hz, 9999
0 to 200%
0 to 9999
0 to 9999
0 to 400Hz
0 to 300%
0 to 400Hz
0 to 300%
0 to 400Hz
0 to 300%
0 to 400Hz
0 to 300%
0 to 400Hz
Minimum
Setting Range
Increments
0.01/0.1A
*2
0.01/0.1A
*2
Initial
Setting
Value
1
0
0.1s
1s
1%
100%
1
0
9999
*2
9999
*2
1
0
1
0
0.1%
150%
0.01Hz
1.5Hz
0.1%
150%
0.01s
0.01s
1
0
1
0
0.01Hz
20Hz
0.1%
150%
1
0
1
0
0.01s
0s
0.1%
150%
0.1times
7times
1%
0%
1
0
0.1V
380/760V
*2
1
0
0.01Hz
6Hz
0.1%
100%
1
9999
1
9999
0.01Hz
0Hz
0.1%
0%
0.01Hz
60Hz
0.1%
100%
0.01Hz
0Hz
0.1%
20%
0.01Hz
60Hz
0.1%
100%
0.01Hz
0Hz
Refer
Customer
to
Setting
Page
53