Mitsubishi Electric FR-A700-A1 Instruction Manual page 13

Dancer control function/tension control function
Table of Contents

Advertisement

PARAMETER LIST
Parameter
733
Taper setting analog input selection
734
Dancer tension setting input selection
737
Stall torque setting
738
Speed limit for stall operation
739
Mechanical loss setting frequency bias
740
Mechanical loss setting frequency 1
741
Mechanical loss 1
742
Mechanical loss setting frequency 2
743
Mechanical loss 2
744
Mechanical loss setting frequency 3
745
Mechanical loss 3
746
Mechanical loss setting frequency 4
747
Mechanical loss 4
748
Mechanical loss setting frequency 5
749
Mechanical loss 5
750
Target winding diameter
751
Dancer input offset
752
Material thickness d1
753
Material thickness d2
754
Material thickness d3
755
Material thickness d4
756
First acceleration time for main speed
757
First deceleration time for main speed
Second acceleration time for main
758
speed
Second deceleration time for main
759
speed
760
Third acceleration time for main speed
761
Third deceleration time for main speed
762
Winding/unwinding selection
763
Line speed input selection
764
Pulse reference for line speed input
765
Voltage reference for line speed input
766
Line speed reference
767
Line speed unit
768
Line speed input filter time constant
769
Filter treatment waiting time
770
Filter time constant
771
r-r' limit value (diameter)
772
r-r' limit disable time
773
Gear ratio numerator (driver side)
774
Gear ratio denominator (follower side)
Speed control proportion term applied
775
diameter 1
Speed control proportion term applied
776
diameter 2
777
Speed control proportional gain 1
778
Speed control proportional gain 2
779
Speed control proportional gain 3
780
Speed control proportional gain 4
781
Winding diameter storage selection
782
Stored winding diameter
Operation time with stored winding
783
diameter
785
Terminal 4 function setting
Number of averaging for winding
786
diameter calculation
787
Taper ratio setting
788
Winding diameter at taper start
789
Dancer tension setting
10
Name
3 to 6, 9999
3 to 6, 9999
0 to 200%
0 to 60Hz
400 to 600%
0 to 400Hz, 9999
400 to 600%
0 to 400Hz, 9999
400 to 600%
0 to 400Hz, 9999
400 to 600%
0 to 400Hz, 9999
400 to 600%
0 to 400Hz, 9999
400 to 600%
1 to 6553mm
400 to 600%
0 to 20mm, 9999
0 to 20mm
0 to 20mm
0 to 20mm
0 to 3600s/360s
0 to 3600s/360s
0 to 3600s/360s
0 to 3600s/360s
0 to 3600s/360s
0 to 3600s/360s
0, 1
0 to 7
0.01 to 200
0.1 to 100%
1 to 6553.4
0, 1, 2, 3
0 to 5s
0 to 100s
0 to 100s
0 to 9.998, 9999
0 to 100s
1 to 65534
1 to 65534
1 to 99%, 9999
1 to 99%, 9999
0 to 1000%, 9999
0 to 1000%, 9999
0 to 1000%, 9999
0 to 1000%, 9999
0, 1
1 to 6553
0 to 100s
1, 2, 9999
0 to 10
0 to 100%, 9999
1 to 6553mm, 9999
1 to 100, 9999
Minimum
Setting Range
Increments
0.001mm
0.001mm
0.001mm
0.001mm
0.1s/0.01s
0.1s/0.01s
0.1s/0.01s
0.1s/0.01s
0.1s/0.01s
0.1s/0.01s
0.001mm
Initial
Setting
Value
1
9999
1
9999
0.1%
20%
0.01Hz
1Hz
1%
500%
0.01Hz
9999
1%
500%
0.01Hz
9999
1%
500%
0.01Hz
9999
1%
500%
0.01Hz
9999
1%
500%
0.01Hz
9999
1%
500%
1mm
1mm
0.01%
500%
9999
1mm
1mm
1mm
15s
15s
15s
15s
15s
15s
1
0
1
0
0.01kpps
30kpps
0.1%
50%
0.1
1000
1
0
0.001s
0.025s
0.01s
0s
0.01s
0s
1mm
0.01s
0s
1
1
1
1
1%
9999
1%
9999
1%
9999
1%
9999
1%
9999
1%
9999
1
0
1mm
1mm
0.01s
0s
1
9999
1
4
0.1%
0%
1mm
9999
0.1
100.0
Refer
Customer
to
Setting
Page
51
51
65
65
64
64
64
64
64
64
64
64
64
64
64
48
16
35
35
35
35
46
46
46
46
46, 65
46
34, 64
33
33
33
33, 49
33, 49
33
38
38
38
38
34
34
47
47
47
47
47
47
37
37
37
44, 51
38
51, 61
51, 61
51