Electra WNG 50 DCI Service Manual page 92

Wng led/lcd dci inverter series
Hide thumbs Also See for WNG 50 DCI:
Table of Contents

Advertisement

TROUBLESHOOTING
14.3.3
Fault Code for Indoor unit
Pressing Mode button for long will activate diagnostic mode by the acknowledgment of 3
short beeps and lighting of COOL and HEAT LED's.
When Indoor diagnostics is displayed, all four LED's (STBY, Operate, Filter, TMR) are on.
Entering diagnostics in STBY mode allows only viewing of status (fault-display).
In diagnostic mode, system problems / information will be indicated by blinking of Heat &
Cool LED's.
The coding method will be as follows:
Heat led will blink 5 times in 5 seconds, and then will be shut off for the next 5 seconds.
Cool Led will blink during the same 5 seconds according to the following table:
No
1
RT-1 is disconnected
2
RT-1 is shorted
3
RT-2 is disconnected
4
RT-2 is shorted
...
Reserved
7
Communication mismatch
8
No Communication
9
No Encoder
10
Reserved
11
Outdoor Unit Fault
...
Reserved
17
Defrost protection
18
Deicing Protection
19
Outdoor Unit Protection
20
Indoor Coil HP Protection
21
Overflow Protection
...
Reserved
24
EEPROM Not Updated
25
Bad EEPROM
26
Bad Communication
27
Using EEPROM data
28
Model A
29
Model B
30
Model C
31
Model D
1 - ON,
0 - OFF
Only one code is shown. Order of priority is lower to the higher number. Diagnostics is
continuously ON as long power is on.
14-6
Fault Name
Revision Y05-02
CONTENT
5
4
3
2
0
0
0
0
0
0
0
1
0
0
0
1
0
0
0
1
0
0
0
1
0
0
1
1
0
0
0
1
0
0
0
1
0
1
0
1
0
1
0
1
0
0
0
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
1
1
1
0
1
1
1
0
1
1
1
0
1
1
1
1
1
1
1
1
1
1
1
Service Manual - WNG 50_60_80 DCI
1
1
0
1
0
1
1
0
1
0
1
1
0
1
0
1
0
1
0
1
0
1
0
1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dci 60

Table of Contents