4
INSTALLATION OF
THE INDOOR UNIT
REMOVAL AND INSTALLATION OF THE
FRONT PANEL
1. Open the front panel.
2. Open the terminal cover.
3. After installation of the wires, replace the terminal cover and
close the grille.
Fig.6
1. Lift the grille
2. Screw
3. Terminal
1
Fig. 6
REFRIGERATION TUBE ROUTING
1. There are five possible routes for installing the refrigeration tube as
shown.
2. For route (6), cut the bottom notch in the rear.
3. For routes (5) or (7), cut the side notches in the rear and in the front
panel.
Fig. 7
4. Lefthand outlet
1. Front
5. Lefthand raw outlet
2. Rear
6. Bottom outlet
3. Rear outlet
7. Righthand outlet
Fig 8
Fig. 7
2
3
4
CONTENT
INSTALLATION OF THE MOUNTING PLATE
1. Figure 9 shows the location of the mounting plate relative to the
unit size. Refer to one of the drawings, according to your unit
length (marked in square).
2. Locate the mounting plate as shown on the wall in a horizontal
position, using a spirit level.
3. Mark the position of the four mounting holes on the wall and drill
four holes to accommodate the dowels.
4. Mount the mounting plate on to the wall by the four screws. Ensure
screws are tightened properly.
Fig. 8
PENETRATION OF WALL FOR TUBING
1. Mark the location of the hole on either side of the mounting
plate as shown. and drill it at a 5 downward angle, as shown.
2. The hole is drilled at an angle, to prevent condensed or rain
water from penetrating back into the room.
Fig. 9
A. OUTDOOR SIDE
1.Drill 70 mm
B. INDOOR SIDE
2.Wall
1
Fig. 9
B
A
5
2

Advertisement