11.4.2 Horizontal Airflow
Automatic airflow direction can be set using remote control; the vane swings left and right within the angles as
stated below.
Manual vertical airflow direction can be set using remote control; the angles of the vane are as stated below and
the positions of the vane are as figure below:
Pattern
Airflow Direction
Patterns at Remote
Control
Vane Angle (°)

11.5 Quiet Operation (Cooling Mode/Cooling Area of Dry Mode)

Purpose
To provide quiet cooling operation compare to normal operation.
o
Control condition
Quiet operation start condition
o
When Quiet button at remote control is pressed Quiet INDICATOR illuminates.
Quiet operation stop condition
o
When one of the following conditions is satisfied, quiet operation stops:
Powerful button is pressed.
Mild Dry Cooling button is pressed.
Stop by OFF/ON button.
OFF Timer activates.
Quiet button is pressed again.
When quiet operation is stopped, operation is shifted to normal operation with previous setting.
When fan speed is changed, quiet operation is shifted to quiet operation of the new fan speed.
When operation mode is changed, quiet operation is shifted to quiet operation of the new mode.
During quiet operation, if ON timer activates, quiet operation maintains.
After off, when on back, quiet operation is not memorized.
Control content
Fan speed is changed from normal setting to quiet setting of respective fan speed. This is to reduce sound of
o
Hi, Me, Lo for 3dB (more than 3dB for some models).
Fan speed for quiet operation is -1 step from setting fan speed.
o
Operation Mode
Cooling and soft dry
2
3
1
2
90
65
28
Vane angle (°)
65 ~ 115
Top View
5
4
1
3
78
4
5
102
115