Connect The Cable To The Indoor Unit - Panasonic CS-S18JKQ Service Manual

Indoor unit and outdoor unit
Hide thumbs Also See for CS-S18JKQ:
Table of Contents

Advertisement

10.2.4 Connect the Cable to the Indoor Unit

1
The inside and outside connecting cable can be connected without removing the front grille.
2
Connecting cable between indoor unit and outdoor unit shall be approved polychloroprene sheathed 4 x 15
2
mm
(1.0~ 1.75HP) or 4 x 2.5 mm
Secure the connecting cable onto the control board with the holder.
This unit must be properly earthed.
Ensure the color of wires of outdoor unit and the terminal numbers are the same to the indoor's respectively.
Earthed lead wire shall be longer than the other lead wires as shown in the figure for the electrical safety in case
of the slipping out of the cord from the anchorage.
10.2.4.1
Wiring Stripping and connecting requirement
Wire stripping
No loose strand when insert
2
(2.0 ~ 2.5HP) flexible cord, type designation 245 IEC 57 or heavier cord.
Terminals on the indoor unit
Colour of wires
Terminals on the outdoor unit
Indoor/outdoor
connecting
terminal board
5 mm
or more
(gap between
wires)
1
2
3
1
2
3
Indoo r and
outdoo r
cable
conne ction
Conductor
fully insert
ACCEPT
23
Terminal
Board
1
2
3
Earth Wire
longe r than
others AC
wires for
safety
reason
Holder
Conductor not
Conductor
over insert
fully insert
PROHIBITED
PROHIBITED

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cu-s24jkqCs-s24jkqCu-s18jkq

Table of Contents