TROUBLESHOOTING
THE ENGINE DOESN’T SWITCH
THE ENGINE DOESN’T STOP
THE MACHINE PERFORMANCE IS
NOT GOOD
THE ENGINE STOPS
FOR THE CHAPTERS: "THE MACHINE DOESN’T SWEEP", "IT DOESN’T SUCKS", "THE SIDE BRUSH
DOESN’T TURN", SEE CHAPTER BATTERY VERSION.
1) CHECK IF THERE IS PETROL IN THE TANK
2) CHECK IF THE TANK TAP IS IN POSITION “ON”
3) CHECK THE CORRECT POSITION /EFFICIENCY OF THE SWITCH
ON/OFF (C1)
4) CHECK THE CONNECTIONS AND EFFICIENCY OF THE SAFETY
MICRO SWITCH MSW
5) INSPECT THE STOPPING ELECTRIC WIRE IN ORDER TO
CHECK ANY EVENTUAL SHORT CIRCUIT (LOSS OF INSULA-
TION) OF THE CABLE
6) CHECK THE AIR FILTER AND SPARK PLUG CONDITION OF THE
PETROL ENGINE (SEE MAINTENANCE CHAPTER)
1) CHECK THE CORRECT POSITION/EFFICIENCY OF THE
SWITCH ON /OFF (C1)
2) CHECK THE STOPPING ENGINE CABLE (WIRE) CONNEC-
TIONS.
1) REVOLUTION PER MINUTE (RPM) OF THE ENGINE: ADJUST IT
UP TO 3000 RPM
1) CHECK THE FUEL LEVEL
2) CHECK THE AIR FILTER AND SPARK PLUG OF THE PETROL
ENGINE
3) CHECK THE EFFICIENCY,CONNECTIONS AND INSULATION
OF THE SWITCH ON/OFF (C1) OF THE SAFETY MICRO
SWITCH (MSW) AND OF THE ELECTRIC WIRE FOR STOP-
PING ENGINE
31