l I n s t a l l a t i o n

C h e c k i n g f o r P r o p e r A i r F l o w

This procedure is needed on W 150 - 400 models if the phase detection option was
not ordered with the dryer.
IMPORTANT: This procedure must be performed before the dryer's air hoses are connect-
ed to the hopper or before loading material into the hopper.
CAUTION: If the air flow direction is incorrect due to improper phase con-
nection, material from the hopper can be pulled into the process heater,
causing permanent damage to this equipment.
1
Turn on the main power to the dryer. Make sure the dryer's disconnect dial is
in the ON position. This powers up the control and the display lights will illu-
minate.
2
Select the setpoint temperature by pressing the select category button
under the setpoint temperature display. Once selected, the number will
flash.
3
Set the drying temperature. Press Setpoint Adjust (+) or (-) buttons or enter a
low temperature (150ºF {66ºC}) on the numeric keypad and press enter.
When configured as a central dryer, the drying temperature can
not be set since there is no process heater in the system.