(2) GT15
Item
GOT NET No.
GOT PLC No.
GOT IP Address
GOT Port No.
(Communication)
GOT Port No.
(Ethernet Download)
Default Gateway
Subnet Mask
Retry
Startup Time
Timeout Time
Delay Time
2 - 10
2.2 Preparatory Procedures for Monitoring
2.2.3 Setting communication interface (Communication settings)
Description
Set the network No. of the GOT.
<Default: 1>
Set the station No. of the GOT.
<Default: 1>
Set the IP address of the GOT.
<Default: 192.168.0.18>
Set the GOT port No. for the connection with the Ethernet module.
<Default: 5019>
Set the GOT port No. for Ethernet download.
<Default: 5014>
Set the router address of the default gateway where the GOT is
connected. (Only for communication via router)
<Default: 0.0.0.0>
Set the subnet mask for the sub network. (Only for connection via
router)
When the sub network is not used, the GOT operates with the
default value.
<Default: 255.255.255.0>
Set the number of retries when a communication error occurs.
When the GOT receives no response from the programmable
controller after retries, the communication times out.
<Default: 3 Times>
Specify the time from when the GOT starts until when the GOT
starts communicating with the programmble controller CPU.
<Default: 3 Sec>
Set the time until the communication times out.
<Default: 3 Sec>
Set the send delay time for reducing the load on the network or
target programmable controller.
<Default: 0ms>
Range
1 to 239
1 to 64
0.0.0.0 to 255.255.255.255
1024 to 5010, 5014 to 65534
(Except for 5011, 5012 and 5013)
1024 to 5010, 5014 to 65534
(Except for 5011, 5012 and 5013)
0.0.0.0 to 255.255.255.255
0.0.0.0 to 255.255.255.255
0 to 5 Times
3 to 255 Sec
3 to 90 Sec
0 to 10000 ( 10 ms)