Memory Initialization
6-4-5

Initializing the Memory Tables

Reference:
It is possible to initialize the numeral memory tables and character string
memory tables in the NT31/NT31C.
When these tables are initialized, the values are returned to those set by the
Support Tool (they are not cleared).
When the memory tables are initialized, they are returned to their initial values
regardless of the setting made for the resume function (page 182).
If ON is set for the Resume Function memory switch, the initial values set with
the Support Tool will not be recorded in the memory tables unless they are ini-
tialized.
• If OFF is set for the Resume Function memory switch, the memory tables
can be initialized just by switching the NT31/NT31C power off and back
on again, or by resetting the NT31/NT31C (page 182).
• The bit memory table merely reflects the statuses of bits at the host and
therefore cannot be initialized.
Section 6-4
147