Initializing The Memory Tables - Omron NT31 Setup Manual

Programmable
Hide thumbs Also See for NT31:
Table of Contents

Advertisement

Memory Initialization

6-4-5 Initializing the Memory Tables

Reference:
It is possible to initialize the numeral memory tables and character string
memory tables in the NT31/NT31C.
When these tables are initialized, the values are returned to those set by the
Support Tool (they are not cleared).
When the memory tables are initialized, they are returned to their initial values
regardless of the setting made for the resume function (page 179).
If ON is set for the Resume Function memory switch, the initial values set with
the Support Tool will not be recorded in the memory tables unless they are initial-
ized.
S If OFF is set for the Resume Function memory switch, the memory tables can
be initialized just by switching the NT31/NT31C power off and back on again,
or by resetting the NT31/NT31C (page 179).
S The bit memory table merely reflects the statuses of bits at the host and there-
fore cannot be initialized.
Section
6-4
145

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Nt31c

Table of Contents