3.2.4 Programming Shortcuts

"Programming Shortcuts" on page 68 lists shortcuts that you can use when
programming the control panel.
To
Do this
To save a point's
Press the
program into
routine displays the next new detector or module.
memory during
Autoprogram or
point programming
To exit from Program
Press the
Change or Status
or press the
Change operations
To display the last
When the blinking cursor is over the first letter of the label field, press
19-character label
the zero key twice to display the label entered for the previous point. If
the last character of the label is a number, pressing the zero key a third
time will increment this number. Once you recall the label, you can edit
each character of the label.
Table 14 Programming Shortcuts

3.2.5 Upload and Download

An upload/download of the control panel may be done at any time by connecting a
personal computer to the EIA-232 port and running the off-line programming routine.
Refer to the Veri•Fire on-line help program for more information.

3.2.6 Key Programming Terms

Here is a list of terms that apply to control panel programming.
All Systems Normal message The message (up to 40 characters) in first two lines of
the LCD display during normal system operation.
Autoprogram A control panel programming function that automatically detects new
devices connected to the SLC, assigns default programming information, and also
determines the total number of programmed devices.
CBE (Control-by-Event) A software function that provides a means to program a
variety of output responses based on various initiating events.
Control module Addressable module that switches power to a Style Y or Style Z NAC.
CPU memory (Central Processing Unit) The nonvolatile element of the CPU that
contains programming information for the control panel.
custom label A custom label is a user-defined message in an LCD display that
identifies a device.
detector sensitivity A detector setting for an ionization or photoelectric detector that
determines the level at which a detector will activate.
installed device An intelligent, addressable detector, control, monitor or relay module
properly addressed and installed in a fire alarm system.
missing device A missing device is a detector or module removed from the SLC (TB6)
that exists in the current program.
Monitor module An addressable monitor module that monitors conventional
alarm-initiating devices.
key. After pressing the
ENTER
ENTER
key until the All Systems Normal screen appears,
BACKSPACE
key.
SYSTEM RESET