Cable Connections - JVC LWT0254-001B-H Instructions Manual

Dome type camera
Table of Contents

Advertisement

Connections & Installation (continued)
16
EN

Cable Connections

CAUTIONS
●Ensure to attach the cover for the ceiling mount. Installation is not possible without attaching the cover.
●The cover prevents penetration of foreign objects into the ceiling mount. Penetration of foreign objects may cause a
malfunction or, in the worst scenario, cause smoking or fire.
Connection Procedure
Make a hole in the ceiling
Make use of the template supplied to
open a hole (R75) for leading the
connection cable through the rear
side of the ceiling.
Remove the Cover
Loosen the Cover Fastening Screw, and turn the Cover in
the anti-clockwise direction to remove the Cover from the
ceiling mount.
● When loosening the Cover Fastening Screw, do so while ensuring
that it does not protrude from the hole.
Cover Fastening Screw
Cover
Ceiling Mount (Terminal
Side)
Lead the cable through the Cover
Make a slit on the (rubber) cap that is attached to the
Cover, followed by leading the cable through. Follow the
diagram below to make the slit.
Cap (Upper)
Connect the cable to this camera
Connect cables to the terminal on the ceiling mount.
Connection cables include alarm signal cable, coaxial
cable, control signal cable and the AC 24 V power cable.
A
Control Signal Cable (A pg. 18)
For connection to RM-P2580.
B
Coaxial cable (A pg. 17)
For connection of monitors and other devices.
C
Alarm signal cable (A pg. 17)
For connection to devices with alarm input/output
terminals.
D
Power cable (A pg. 18)
For connection to an AC 24 V power supply. Listed class
2 input only.
Attach the Cover
Safety Wire
Mounting
Attach the Cover to the ceiling mount by following
Hole
procedure of Step
A
Attach the cover upon aligning the hole with the Safety
Wire Mounting Hole on the ceiling mount, followed by
turning it in the clockwise direction.
B
Fasten the Cover Fastening Screw.
A Control Signal Cable
Connect to "To Camera" terminal of RM-
P2580 and to subsequent cameras.
B Coaxial Cable
Connect to the monitor, etc.
C Alarm Signal Cable
Connect to devices with
alarm input terminal.
Connect to AC 24 V power
D Power Cable
supply. Listed class 2 input
only.
in the reverse order.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tk-c625eTk-c625uTk-c625